Worked example
Example: 45 bar(a) / 400 °C to 4 bar(a), exhaust 200 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet steam pressure (absolute) | 45.000 bar |
| Inlet steam condition | Superheated at the temperature below |
| Inlet steam temperature (superheated only) | 400.00 °C |
| Exhaust pressure (absolute) | 400.00 kPa |
| Measured exhaust temperature (superheated exhaust) | 200.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Isentropic efficiency | 63.099 % |
| Actual enthalpy drop | 344.57 kJ/kg |
| Isentropic enthalpy drop | 546.07 kJ/kg |
| Exhaust enthalpy | 2,861.0 kJ/kg |
| Isentropic exhaust enthalpy | 2,659.5 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\eta_i = \frac{h_1 - h_2}{h_1 - h_{2s}} \qquad h_{2s} = h(p_2, s_1) \qquad h_2 = h(p_2, T_2)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_1\) | inlet pressure, absolute | Pa |
| \(\text{state}\) | dry saturated or superheated inlet | – |
| \(T_1\) | inlet temperature (superheated) | K |
| \(p_2\) | exhaust pressure, absolute | Pa |
| \(T_2\) | measured exhaust temperature | K |
| \(\eta_i\) | isentropic efficiency | – |
| \(h_1 - h_2\) | actual enthalpy drop | J/kg |
| \(h_1 - h_{2s}\) | isentropic enthalpy drop | J/kg |
| \(h_2\) | exhaust enthalpy | J/kg |
| \(h_{2s}\) | isentropic exhaust enthalpy | J/kg |
| \(s_1\) | inlet entropy | J/(kg·K) |
Method and standards
Isentropic efficiency as the ratio of actual to isentropic enthalpy drop, the enthalpy-drop method used in turbine performance testing (ASME PTC 6 uses the same idea for its sections). Enthalpies and entropies from FireCAD's IAPWS-IF97.
Where it is used
- Routine performance monitoring of back-pressure and extraction turbines.
- Before and after an overhaul, to see what the repair gained.
- Checking a vendor's efficiency claim at site conditions.
Common mistakes
- Using an exhaust temperature measured too close to a desuperheater or drain.
- Ignoring the pressure drop across stop and control valves when the inlet is measured upstream of them.
- Applying it to wet exhaust.
Assumptions and limits
- Exhaust superheated (vapour) for a measured temperature to fix its state; supercritical exhaust is not accepted (not reached at exhaust pressures in practice); steady flow; heat loss from the casing neglected.
- An efficiency outside 0–100 % is rejected as a reading error.
References
- IAPWS R7-97(2012) IF97
- ASME PTC 6 (enthalpy-drop efficiency concept)
Questions and answers
How do I find a turbine's efficiency from plant readings?
Compare the actual enthalpy drop with the isentropic one. Steam at 45 bar(a) and 400 °C leaving at 4 bar(a) and 200 °C dropped 345 kJ/kg, against 546 kJ/kg isentropically: 63.1 % efficient.
Why can't I use it on a condensing turbine?
Its exhaust is wet, and temperature alone does not tell the dryness. For condensing turbines measure the efficiency of the superheated sections, or find the exhaust enthalpy from a condenser heat balance.
What does falling efficiency tell me?
Deposits on the blades, worn seals or damaged nozzles. Track it at the same load and pressures; a drop of a few points is worth an inspection.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.