FireCADCalc

Steam Turbine Exhaust Dryness and Wetness

Dryness fraction and moisture of steam leaving a turbine from the inlet conditions, exhaust pressure and isentropic efficiency, actual and isentropic (IAPWS-IF97).

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Steam turbineCondenser and cooling tower

Inputs

Examples: 66 bar(a) / 485 °C to 0.1 bar(a), 82 %45 bar(a) / 400 °C to 0.12 bar(a), 75 %Saturated 17.5 bar(a) to 3 bar(a), 60 %

Results

Exhaust dryness fraction (1 = dry or superheated)92.465%
Exhaust moisture (wetness)7.5348%
Dryness after isentropic expansion81.349%
Exhaust temperature49.420°C
Exhaust enthalpy2,410.7kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 66 bar(a) / 485 °C to 0.1 bar(a), 82 %. The inputs, in the units selected above:

InputValue
Inlet steam pressure (absolute)66.000 bar
Inlet steam conditionSuperheated at the temperature below
Inlet steam temperature (superheated only)485.00 °C
Exhaust pressure (absolute)10.000 kPa
Turbine isentropic efficiency82.000 %

Applying the formula below gives:

ResultValue
Exhaust dryness fraction (1 = dry or superheated)91.067 %
Exhaust moisture (wetness)8.9328 %
Dryness after isentropic expansion81.803 %
Exhaust temperature45.808 °C
Exhaust enthalpy2,370.2 kJ/kg

Open this example in the calculator and change any input.

Formula

\(h_2 = h_1 - \eta_i\left[h_1 - h(p_2, s_1)\right] \qquad x_2 = \frac{h_2 - h_f}{h_g - h_f} \qquad y_2 = 1 - x_2 \qquad x_{2s} = \frac{s_1 - s_f}{s_g - s_f}\)

Variables

Symbol Meaning SI unit
\(p_1\) inlet pressure, absolute Pa
\(\text{state}\) dry saturated or superheated inlet –
\(T_1\) inlet temperature (superheated) K
\(p_2\) exhaust pressure, absolute Pa
\(\eta_i\) turbine isentropic efficiency –
\(x_2\) exhaust dryness fraction –
\(y_2\) exhaust moisture –
\(x_{2s}\) dryness after isentropic expansion –
\(T_2\) exhaust temperature K
\(h_2\) exhaust enthalpy J/kg
\(h_1\), \(s_1\) inlet enthalpy and entropy J/kg, J/(kg·K)
\(h_f\), \(h_g\), \(s_f\), \(s_g\) saturated liquid and vapour enthalpy and entropy at \(p_2\) J/kg, J/(kg·K)

Method and standards

Exhaust state from the isentropic-efficiency expansion; dryness from saturation properties at the exhaust pressure, all by FireCAD's IAPWS-IF97. A superheated exhaust shows dryness 1.

Where it is used

  • Checking blade erosion risk when inlet temperature or condenser vacuum changes.
  • Condenser heat balances, which need the exhaust dryness.
  • Choosing inlet superheat or reheat for a new turbine.

Common mistakes

  • Using the isentropic dryness as the real one.
  • Taking the condenser pressure as the last-stage exit pressure when the exhaust hood loses pressure.
  • Using gauge pressures.

Assumptions and limits

  • One expansion with constant efficiency; equilibrium wet steam (no supercooling).

References

  • IAPWS R7-97(2012) IF97

Questions and answers

How wet is turbine exhaust steam?

Expanding from 66 bar(a) and 485 °C to 0.1 bar(a) with 82 % efficiency, the exhaust is 91.1 % dry, 8.9 % moisture. An ideal (isentropic) turbine would leave it only 81.8 % dry.

What wetness is allowed?

The turbine maker sets the limit; this page warns below 88 % dryness (12 % moisture), a commonly used level rather than a sourced limit. More moisture erodes the last-stage blades. Reheat or higher inlet superheat keeps it down.

Why is the real exhaust drier than the ideal one?

Turbine losses turn into heat in the steam, which re-evaporates some of the moisture.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.