Steam flow a turbine stage group passes at new inlet and outlet pressures and inlet temperature, from a design point, by Stodola's ellipse law (IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Steam turbine

Inputs

Examples: Lower inlet pressureHigher exhaust

Results

Applies to a group of stages without control-valve throttling between the pressures used; nozzle-governed first stages need the valve points.

Flow at the new conditions92.055t/h
Flow ratio92.055%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Lower inlet pressure. The inputs, in the units selected above:

InputValue
Design flow100.00 t/h
Design inlet pressure (absolute)87.000 bar
Design inlet temperature515.00 °C
Design outlet pressure (absolute)2.5000 bar
New inlet pressure (absolute)80.000 bar
New inlet temperature510.00 °C
New outlet pressure (absolute)2.5000 bar

Applying the formula below gives:

ResultValue
Flow at the new conditions92.055 t/h
Flow ratio92.055 %

Open this example in the calculator and change any input.

Formula

\(\frac{\dot m}{\dot m_0} = \sqrt{\frac{p_{in}^2 - p_{out}^2}{p_{in,0}^2 - p_{out,0}^2}}\sqrt{\frac{p_{in,0}v_{in,0}}{p_{in}v_{in}}}\)

Variables

Symbol Meaning SI unit
\(\dot m_0\) Design flow kg/s
\(p_{in,0}\) Design inlet pressure (absolute) Pa
\(T_{in,0}\) Design inlet temperature K
\(p_{out,0}\) Design outlet pressure (absolute) Pa
\(p_{in}\) New inlet pressure (absolute) Pa
\(T_{in}\) New inlet temperature K
\(p_{out}\) New outlet pressure (absolute) Pa
\(\dot m\) Flow at the new conditions kg/s
\(\dot m/\dot m_0\) Flow ratio -

Method and standards

Stodola's ellipse (cone) law for a group of turbine stages: with fixed geometry the flow is proportional to √((p_in² − p_out²)/(p_in v_in)), so the flow at new conditions follows from a known design point. Inlet specific volumes from FireCAD's IAPWS-IF97.

Where it is used

  • Turbine performance monitoring.
  • Off-design studies.

Common mistakes

  • Using gauge pressures in the squares.

Assumptions and limits

  • Fixed stage geometry.
  • Both inlet states must be superheated (or supercritical) steam; a liquid inlet state is rejected.

References

  • Stodola's ellipse (cone) law ṁ ∝ √((p_in² − p_out²)/(p_in v_in)); specific volumes from IAPWS-IF97

Questions and answers

What does the ellipse law say?

A group of turbine stages behaves like a nozzle: flow follows inlet pressure and density, softened by the outlet pressure.

Use?

Predicting extraction pressures and flows at part load, or checking for a damaged or fouled stage group.

Choked groups?

When the outlet is much lower than the inlet, flow is nearly proportional to p_in/√(p_in v_in).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.