FireCADCalc

Steam Nozzle Exit Velocity, Critical Pressure and Areas

Exit velocity of steam from a nozzle from the enthalpy drop, the critical (choked) pressure and throat mass flux found on the IF97 isentrope, and throat and exit areas for a flow.

Thermal power plantSugar mill and cogenerationPulp and paperIAPWS-IF97 (water and steam)Steam turbineBoiler attendant and boiler operator examinations

Inputs

Examples: 10 bar(a) 250 °C to 2 bar(a), 95 %, 1 kg/sDry saturated 8 bar(a) to 1.5 bar(a), 90 %20 bar(a) 300 °C to 14 bar(a) (convergent), 97 %, 50 m/s in

Results

The exit pressure is above the critical pressure: a convergent nozzle is enough, and the throat is the exit (throat and exit values are the same).

With an approach velocity the flux uses the stagnation enthalpy, but the pressures and the critical ratio are referred to the static inlet pressure p₁.

Isentropic enthalpy drop to the exit85.984kJ/kg
Actual enthalpy drop η Δh_s83.404kJ/kg
Exit velocity √(2 Δh + V₁²)411.47m/s
Critical (throat) pressure10.968bar
Critical pressure ratio0.54842
Throat velocity411.47m/s
Throat area for the flow805.38mm²
Exit area for the flow805.38mm²
Dryness at the exit (1 when superheated)100.00%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 bar(a) 250 °C to 2 bar(a), 95 %, 1 kg/s. The inputs, in the units selected above:

InputValue
Inlet pressure (absolute)10.000 bar
Inlet steamSuperheated at the temperature below
Inlet temperature (superheated)250.00 °C
Exit pressure (absolute)2.0000 bar
Nozzle efficiency95.000 %
Approach velocity0 m/s
Steam flow3,600.0 kg/h

Applying the formula below gives:

ResultValue
Isentropic enthalpy drop to the exit315.75 kJ/kg
Actual enthalpy drop η Δh_s299.96 kJ/kg
Exit velocity √(2 Δh + V₁²)774.54 m/s
Critical (throat) pressure5.4468 bar
Critical pressure ratio0.54468
Throat velocity513.59 m/s
Throat area for the flow722.35 mm²
Exit area for the flow1,110.9 mm²
Dryness at the exit (1 when superheated)97.139 %

Open this example in the calculator and change any input.

Formula

\(V_2 = \sqrt{2\, \eta_n\, \Delta h_s + V_1^2} = 44.72 \sqrt{\eta_n\, \Delta h_s\ [\text{kJ/kg}]}\ (V_1 = 0)\)

\(G = \rho \sqrt{2 (h_0 - h)}\ \text{on}\ s = s_1, \quad p_c: G = G_{max}\)

\(A_t = \frac{\dot m\, v_t}{V_t}, \quad A_2 = \frac{\dot m\, v_2}{V_2}\)

Variables

Symbol Meaning SI unit
\(p_1\) Inlet pressure (absolute) Pa
\(\text{inlet}\) Inlet steam -
\(T_1\) Inlet temperature (superheated) K
\(p_2\) Exit pressure (absolute) Pa
\(\eta_n\) Nozzle efficiency -
\(V_1\) Approach velocity m/s
\(\dot m\) Steam flow kg/s
\(\Delta h_s\) Isentropic enthalpy drop to the exit J/kg
\(\Delta h\) Actual enthalpy drop η Δh_s J/kg
\(V_2\) Exit velocity √(2 Δh + V₁²) m/s
\(p_c\) Critical (throat) pressure Pa
\(p_c/p_1\) Critical pressure ratio -
\(V_t\) Throat velocity m/s
\(A_t\) Throat area for the flow m²
\(A_2\) Exit area for the flow m²
\(x_2\) Dryness at the exit (1 when superheated) -

Method and standards

Steady adiabatic flow: kinetic energy gained equals enthalpy lost. The critical (choked) pressure is where the mass flux on the IF97 isentrope is greatest.

Worked example

Steam at 10 bar absolute and 250 °C expands in a nozzle to 2 bar absolute; nozzle efficiency 95 %.

  • h₁ = 2943 kJ/kg; isentropic h₂ = 2627 kJ/kg; drop 315.7 kJ/kg
  • Actual drop = 0.95 × 315.7 = 300.0 kJ/kg
  • V₂ = 44.72 × √300.0 = 774.5 m/s
  • Critical pressure = 0.545 × 10 = 5.45 bar: 2 bar is lower, so the nozzle is convergent–divergent

Where it is used

  • Boiler operator and engineer examinations.
  • Steam turbine and ejector nozzles.
  • Safety valve and orifice flow understanding.

Common mistakes

  • Forgetting the 2 and the kJ to J (44.72 comes from √2000).
  • Using the exit pressure as the throat pressure.
  • Applying the efficiency to the velocity instead of the enthalpy drop.

Assumptions and limits

  • Equilibrium expansion; supersaturation not modelled.
  • Nozzle efficiency applied to the whole drop. For a convergent nozzle (exit above the critical pressure) the throat is the exit, so the throat values equal the exit values at the actual state.
  • With an approach velocity the flux uses the stagnation enthalpy h₀, while the critical pressure ratio is referred to the static inlet pressure, not the stagnation pressure used in some textbooks.
  • The critical pressure is searched between 0.2 and 0.999 p₁; a result at the edge is flagged.

References

  • IAPWS-IF97 (water and steam)
  • Isentropic nozzle flow (textbook)

Questions and answers

What exit velocity does steam at 10 bar(a), 250 °C reach expanding to 2 bar(a) at 95 % efficiency?

The isentropic drop is 315.7 kJ/kg, the actual 300.0 kJ/kg, so V₂ = √(2 × 300 000) = 774.5 m/s (44.72 √(Δh in kJ/kg)).

What is the critical pressure ratio?

Found on the steam's own isentrope: 0.545 for this superheated steam and 0.577 for dry saturated steam, matching the textbook 0.546 and 0.577.

When is a divergent part needed?

When the exit pressure is below the critical pressure; otherwise a convergent nozzle is enough.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.