FireCADCalc

Impulse Turbine Velocity Triangles and Blade Efficiency

Velocity triangles of a single-stage impulse (De Laval) turbine: blade angles, whirl, work per kg, power, axial thrust and diagram efficiency, with the maximum efficiency.

Thermal power plantSugar mill and cogenerationPulp and paperSteam turbineBoiler attendant and boiler operator examinations

Inputs

Examples: 600 m/s at 20°, 250 m/s blades, symmetric, k 0.9, 1 kg/s900 m/s at 16°, 400 m/s, symmetric, k 0.85, 2 kg/s500 m/s at 20°, 200 m/s, outlet 25°, k 0.9

Results

Whirl velocity at inlet V₁ cos α563.82m/s
Flow velocity at inlet V₁ sin α205.21m/s
Relative velocity at inlet374.96m/s
Blade inlet angle33.182°
Relative velocity at outlet337.46m/s
Change in whirl velocity596.25m/s
Work per kg of steam U ΔV_w149.06kJ/kg
Power developed149.06kW
Axial thrust20.521N
Diagram (blading) efficiency 2 U ΔV_w / V₁²82.812%
Blade speed ratio U / V₁0.41667
Best blade speed ratio cos α / 20.46985
Maximum diagram efficiency at the best ratio83.887%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 600 m/s at 20°, 250 m/s blades, symmetric, k 0.9, 1 kg/s. The inputs, in the units selected above:

InputValue
Steam velocity leaving the nozzle600.00 m/s
Nozzle angle to the plane of the wheel20.000 °
Mean blade speed250.00 m/s
Blade outlet angleSymmetric blades (outlet = inlet angle)
Blade outlet angle (when given)30.000 °
Blade velocity coefficient V_r2 / V_r10.90000 -
Steam flow3,600.0 kg/h

Applying the formula below gives:

ResultValue
Whirl velocity at inlet V₁ cos α563.82 m/s
Flow velocity at inlet V₁ sin α205.21 m/s
Relative velocity at inlet374.96 m/s
Blade inlet angle33.182 °
Relative velocity at outlet337.46 m/s
Change in whirl velocity596.25 m/s
Work per kg of steam U ΔV_w149.06 kJ/kg
Power developed149.06 kW
Axial thrust20.521 N
Diagram (blading) efficiency 2 U ΔV_w / V₁²82.812 %
Blade speed ratio U / V₁0.41667
Best blade speed ratio cos α / 20.46985
Maximum diagram efficiency at the best ratio83.887 %

Open this example in the calculator and change any input.

Formula

\(V_{w1} = V_1 \cos\alpha, \quad V_{f1} = V_1 \sin\alpha, \quad \tan\beta_1 = \frac{V_{f1}}{V_{w1} - U}\)

\(V_{r2} = k\, V_{r1}, \quad \Delta V_w = V_{w1} + V_{r2} \cos\beta_2 - U\)

\(w = U\, \Delta V_w, \quad \eta_d = \frac{2 U \Delta V_w}{V_1^2}, \quad \eta_{max} = \frac{\cos^2\alpha}{2}\,(1 + k\, c), \quad c = \frac{\cos\beta_2}{\cos\beta_1}\ (= 1\ \text{for symmetric blades})\)

\(P = \dot m\,w, \quad F_a = \dot m\,(V_{f1} - V_{f2}), \quad V_{f2} = V_{r2}\sin\beta_2\)

Variables

Symbol Meaning SI unit
\(V_1\) Steam velocity leaving the nozzle m/s
\(\alpha\) Nozzle angle to the plane of the wheel rad
\(U\) Mean blade speed m/s
\(\text{blades}\) Blade outlet angle -
\(\beta_2\) Blade outlet angle (when given) rad
\(k\) Blade velocity coefficient V_r2 / V_r1 -
\(\dot m\) Steam flow kg/s
\(V_{w1}\) Whirl velocity at inlet V₁ cos α m/s
\(V_{f1}\) Flow velocity at inlet V₁ sin α m/s
\(V_{r1}\) Relative velocity at inlet m/s
\(\beta_1\) Blade inlet angle rad
\(V_{r2}\) Relative velocity at outlet m/s
\(\Delta V_w\) Change in whirl velocity m/s
\(w\) Work per kg of steam U ΔV_w J/kg
\(P\) Power developed W
\(F_a\) Axial thrust N
\(\eta_d\) Diagram (blading) efficiency 2 U ΔV_w / V₁² -
\(\rho\) Blade speed ratio U / V₁ -
\(\rho_{opt}\) Best blade speed ratio cos α / 2 -
\(\eta_{max}\) Maximum diagram efficiency at the best ratio -

Method and standards

Euler's turbine equation applied to the inlet and outlet velocity triangles of a single impulse stage.

Worked example

Steam leaves the nozzle at 600 m/s at 20° to the wheel plane; mean blade speed 250 m/s; symmetric blades; blade friction factor 0.9.

  • V_w1 = 563.8, V_f1 = 205.2 m/s; V_r1 = 375.0 m/s at β₁ = 33.2°
  • V_r2 = 337.5 m/s; ΔV_w = 563.8 + 337.5 cos 33.2° − 250 = 596.2 m/s
  • Work = 250 × 596.2 = 149.1 kJ/kg; η = 2 × 149 062 / 600² = 82.8 %

Where it is used

  • Boiler operator and engineer examinations.
  • Understanding steam turbine stage design.
  • Checking blade speed against nozzle velocity.

Common mistakes

  • Measuring angles from the axis instead of the wheel plane.
  • Forgetting the sign of the outlet whirl.
  • Using V₁² without the factor 2.

Assumptions and limits

  • Single stage, single row; no leakage or windage.
  • Angles measured from the plane of the wheel.
  • A blade speed above the whirl velocity gives negative work, with a note. If the outlet angle makes the maximum-efficiency ratio unphysical (above 100 %), η_max is not shown.
  • With a given outlet angle, a relative inlet angle within 1° of 90° (blade speed equal to the whirl component) is rejected: cos β₁ is then near zero and the maximum efficiency is not defined.

References

  • Velocity triangles of an impulse stage (textbook)

Questions and answers

What does steam at 600 m/s, nozzle angle 20°, blade speed 250 m/s give with symmetric blades and k = 0.9?

Blade inlet angle 33.2°, work 149.1 kJ/kg and a diagram efficiency of 82.8 %.

What is the best blade speed?

For symmetric blades, U/V₁ = cos α / 2 = 0.47, giving cos²α (1 + k)/2 = 83.9 %.

Where does the axial thrust come from?

From the change in the flow (axial) velocity across the blades, which friction (k below 1) makes unequal.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.