FireCADCalc

Gas Turbine Exhaust Flow from Heat Rate

Gas turbine exhaust mass flow and exhaust heat from its power output, heat rate and exhaust temperature, by an energy balance, for HRSG design.

Thermal power plantSugar mill and cogenerationPulp and paperBoiler

Inputs

Examples: 30 MW GT, heat rate 10 500 kJ/kWh, exhaust 540 °C, ambient 30 °C5 MW GT, 12 500 kJ/kWh, 510 °C, 35 °C150 MW GT, 9800 kJ/kWh, 590 °C, 25 °C

Results

An estimate: use the gas turbine maker's exhaust flow at site conditions for design.

Exhaust gas flow1,409,641kg/h
Heat in the exhaust above ambient252.21MW
Fuel heat input408.33MW
Gas turbine efficiency36.735%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 MW GT, heat rate 10 500 kJ/kWh, exhaust 540 °C, ambient 30 °C. The inputs, in the units selected above:

InputValue
Gas turbine power output30.000 MW
Gas turbine heat rate (on NCV)10,500 kJ/kWh
Exhaust temperature540.00 °C
Ambient (compressor inlet) temperature30.000 °C
Mean specific heat of the exhaust1.1200 kJ/(kg·K)
Other losses (generator, lube oil, casing), share of fuel heat2.0000 %

Applying the formula below gives:

ResultValue
Exhaust gas flow351,366 kg/h
Heat in the exhaust above ambient55.750 MW
Fuel heat input87.500 MW
Gas turbine efficiency34.286 %

Open this example in the calculator and change any input.

Formula

\(\dot Q_f = P\,HR \qquad \dot Q_{exh} = \dot Q_f\,(1 - \lambda) - P \qquad \dot m_{exh} = \frac{\dot Q_{exh}}{\bar c_p\,(T_{exh} - T_a)} \qquad \eta = \frac{1}{HR}\)

Variables

Symbol Meaning SI unit
\(P\) power output W
\(HR\) heat rate on NCV J/J
\(T_{exh}\) exhaust temperature K
\(T_a\) ambient temperature K
\(\bar c_p\) mean exhaust specific heat J/(kg·K)
\(\lambda\) other losses, share of fuel heat –
\(\dot m_{exh}\) exhaust flow kg/s
\(\dot Q_{exh}\) exhaust heat above ambient W
\(\dot Q_f\) fuel heat input W
\(\eta\) efficiency –

Method and standards

Energy balance: fuel heat leaves as power, other losses and exhaust heat above ambient.

Where it is used

  • Early HRSG sizing.
  • Cogeneration feasibility with gas turbines.
  • Checking exhaust flow from site readings.

Common mistakes

  • Mixing ISO and site heat rates.
  • Using GCV-based heat rate with NCV assumptions.
  • Ignoring the fuel mass in the exhaust (a few per cent).

Assumptions and limits

  • Steady state; mean specific heat. The flow is inversely proportional to the c̄_p entered (5 % error in c̄_p gives about 5 % in flow). The default 1120 J/(kg·K) is a round figure for gas turbine exhaust; for a better value compute the mean c_p of your exhaust composition over the temperature range with the gas properties calculator.

References

  • Energy balance of the gas turbine

Questions and answers

How much exhaust does a 30 MW gas turbine make?

At a heat rate of 10 500 kJ/kWh it burns 87.5 MW of fuel; after 2 % other losses 55.8 MW leaves in the exhaust, and at 540 °C over 30 °C ambient that is about 98 kg/s.

Why estimate it?

For early HRSG and waste heat studies when the maker's data at site conditions is not yet available.

How accurate is it?

Within a few per cent if the heat rate and exhaust temperature are at the same conditions; use the maker's exhaust flow for design.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.