Worked example
Example: Furnace wall tube: water 300 °C, h 20 000, 250 kW/m², 63.5 x 6 mm, k 40. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid temperature inside the tube | 300.00 °C |
| Inside film coefficient | 20,000 W/(m²·K) |
| Heat flux on the outside surface | 250.00 kW/m² |
| Tube outside diameter | 63.500 mm |
| Wall thickness | 6.0000 mm |
| Wall thermal conductivity | 40.000 W/(m·K) |
| Inside scale (fouling) resistance | 0 m²·K/W |
Applying the formula below gives:
| Result | Value |
|---|---|
| Outside wall temperature (hottest) | 356.98 °C |
| Mean wall temperature | 336.19 °C |
| Inside wall temperature | 315.41 °C |
| Rise across the inside film | 15.413 K |
| Rise across the scale | 0 K |
| Rise across the wall | 41.564 K |
Open this example in the calculator and change any input.
Formula
\(d_i = d_o - 2w \qquad q_i'' = q''\,\frac{d_o}{d_i} \qquad \Delta T_f = \frac{q_i''}{h_i} \qquad \Delta T_s = q_i''\,R_s \qquad \Delta T_w = \frac{q''\,(d_o/2)\ln(d_o/d_i)}{k_w}\)
\(T_i = T_f + \Delta T_f + \Delta T_s \qquad T_o = T_i + \Delta T_w \qquad T_m = T_i + \frac{\Delta T_w}{2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_f\) | fluid temperature | K |
| \(h_i\) | inside film coefficient | W/(m²·K) |
| \(q''\) | heat flux on the outside surface | W/m² |
| \(d_o\) | outside diameter | m |
| \(w\) | wall thickness | m |
| \(k_w\) | wall conductivity | W/(m·K) |
| \(R_s\) | scale resistance | m²·K/W |
| \(T_o\) | outside wall temperature | K |
| \(T_m\) | mean wall temperature | K |
| \(T_i\) | inside wall temperature | K |
| \(\Delta T_f\) | rise across the film | K |
| \(\Delta T_s\) | rise across the scale | K |
| \(\Delta T_w\) | rise across the wall | K |
| \(d_i\) | inside diameter | m |
| \(q_i''\) | flux at the inside surface | W/m² |
Method and standards
One-dimensional radial conduction with the heat flux referred to the outside surface; film and scale resistances on the inside area.
Where it is used
- Checking furnace and superheater tubes for overheating.
- Explaining tube failures after scale build-up.
- Setting limits for heat flux at low circulation.
Common mistakes
- Using the average flux where the peak flux is much higher.
- Ignoring scale or oxide on the inside.
- Using the conductivity of the wrong material or temperature.
Assumptions and limits
- Uniform flux around the tube, referred to the outside surface; steady state. Furnace wall tubes are heated on one side with a peak flux at the crown: enter the peak local flux for the hottest point.
- The mean wall temperature is the arithmetic mean of the inside and outside values.
- A note appears above about 450 °C on the outside wall.
References
- Conduction through a cylindrical wall with film and scale resistances in series
Questions and answers
How hot does a furnace tube run?
With water at 300 °C, an inside coefficient of 20 000 W/(m²·K) and 250 kW/m² on a 63.5 × 6 mm tube, the inside wall is 315 °C, the outside 357 °C and the mean 336 °C.
What does scale do?
Just 0.0001 m²·K/W of scale adds about 31 K to the metal at this flux: scale is how clean tubes become overheated tubes.
Which temperature do codes use?
Pressure-part design usually uses the mean wall temperature; oxidation limits use the outside surface. Your code sets which. The mean here is the arithmetic mean of the inside and outside wall temperatures, a close approximation to the mean of the logarithmic profile for boiler tubes.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.