FireCADCalc

Tube Bend Wall Thinning and Ovality

Wall thickness at the outside and inside of a tube bend from the bend radius (constant-volume geometry) and ovality from measured diameters.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: 2 in tube, R = 2DTight bend 1.5D

Results

Geometric estimate (wall stretches with the fibre length). Real bends thin somewhat less; the minimum thickness after bending and ovality limits come from the design code.

Extrados (outside) thickness3.0000mm
Intrados (inside) thickness6.0000mm
Extrados thinning25.000%
Ovality (D_max − D_min)/D6.5617%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 in tube, R = 2D. The inputs, in the units selected above:

InputValue
Tube outside diameter50.800 mm
Wall thickness before bending4.5000 mm
Bend centreline radius100.00 mm
Largest measured diameter52.500 mm
Smallest measured diameter49.500 mm

Applying the formula below gives:

ResultValue
Extrados (outside) thickness3.5885 mm
Intrados (inside) thickness6.0322 mm
Extrados thinning20.255 %
Ovality (D_max − D_min)/D5.9055 %

Open this example in the calculator and change any input.

Formula

\(t_e = t_0\frac{R}{R + D/2}, \quad t_i = t_0\frac{R}{R - D/2}, \quad O = \frac{D_{max} - D_{min}}{D}\)

Variables

Symbol Meaning SI unit
\(D\) Tube outside diameter m
\(t_0\) Wall thickness before bending m
\(R\) Bend centreline radius m
\(D_{max}\) Largest measured diameter m
\(D_{min}\) Smallest measured diameter m
\(t_e\) Extrados (outside) thickness m
\(t_i\) Intrados (inside) thickness m
\(1 − t_e/t_0\) Extrados thinning -
\(O\) Ovality (D_max − D_min)/D -

Method and standards

Constant-volume geometry: the wall at the extrados stretches, and at the intrados shortens, with the length of the fibre at R ± D/2 relative to the centreline, so the thickness changes in inverse proportion. Ovality is the difference of the measured diameters over the nominal diameter.

Where it is used

  • Bend specification and inspection.
  • Tube failure analysis.

Common mistakes

  • Bend radius measured to the inside.

Assumptions and limits

  • Constant volume, no axial feed; the wall thickness must be less than D/2.
  • The outer fibre radius R + D/2 is used for the whole wall; the mid-wall radius would give slightly less thinning, and real bends with axial push thin less still. The code minimum thickness after bending is not checked.

References

  • Constant-volume fibre-length geometry: t_e = t₀ R/(R + D/2)
  • t_i = t₀ R/(R − D/2); ovality = (D_max − D_min)/D

Questions and answers

Why does the outside thin?

The outer fibre stretches as the tube bends, so its wall gets thinner.

Tight bends?

At R = 1.5 D the outer wall thins by about a quarter in this estimate.

Is this the code thickness?

No: codes give the minimum thickness after bending; use this to estimate what bending will do.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.