Worked example
Example: 60 m3 to 160 bar. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water volume of the system | 60.000 m³ |
| Water temperature | 30.000 °C |
| Starting pressure (absolute) | 1.0132 bar |
| Test pressure (absolute) | 160.00 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water mass to add | 417.56 kg |
| Water volume to add (at starting pressure) | 419.38 L |
| Pressure fall for each litre leaked (pressure per L) | 0.37910 bar |
Open this example in the calculator and change any input.
Formula
\(\Delta m = V[\rho(p_2, T) - \rho(p_1, T)], \quad \Delta V = \frac{\Delta m}{\rho_1}, \quad \Delta p/L = \frac{p_2 - p_1}{\Delta V / 0.001\ \text{m}^3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Water volume of the system | m³ |
| \(T\) | Water temperature | K |
| \(p_1\) | Starting pressure (absolute) | Pa |
| \(p_2\) | Test pressure (absolute) | Pa |
| \(\Delta m\) | Water mass to add | kg |
| \(\Delta V\) | Water volume to add (at starting pressure) | m³ |
| \(\Delta p/L\) | Pressure fall for each litre leaked | Pa per L |
| \(\rho_1, \rho(p, T)\) | Water density at the starting pressure; at pressure p and T (IF97) | kg/m³ |
Method and standards
Mass balance at constant temperature: the water added is the system volume times the rise in IAPWS-IF97 density from the starting to the test pressure. The pressure fall per litre leaked is the pressure rise divided by that added volume in litres, a linear (constant compressibility) estimate.
Where it is used
- Hydrotest planning.
- Leak-rate judgement during tests.
Common mistakes
- Ignoring trapped air.
Assumptions and limits
- Rigid shell; constant temperature. Shell dilation can add a comparable volume for large thin vessels, so the water needed is then higher and the pressure fall per litre lower.
References
- Mass balance with IAPWS-IF97 densities at both pressures (rigid shell); test pressure itself is a code value entered by the user
Questions and answers
Why so little water?
Water is stiff: at 30 °C the IF97 densities give about 0.045 % volume change per 10 bar.
Why does a small leak drop the pressure fast?
Losing the little compression water releases the whole pressure rise.
Air in the system?
Trapped air absorbs far more water and makes the test slow and unsafe: vent it.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.