Worked example
Example: 50 t/h, exit quality 10 %, 68 bar(a), 4 downcomers 250 mm, 400 risers 50 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam generated | 50,000 kg/h |
| Steam quality at riser exit | 10.000 % |
| Drum pressure (absolute) | 68.000 bar |
| Number of downcomers | 4.0000 - |
| Downcomer inside diameter | 250.00 mm |
| Number of risers (evaporator tubes) | 400.00 - |
| Riser inside diameter | 50.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Circulation ratio (1/x from the quality entered) | 10.000 |
| Circulating water flow | 500,000 kg/h |
| Downcomer water velocity | 0.95163 m/s |
| Riser inlet velocity | 0.23791 m/s |
| Riser exit mixture velocity (homogeneous) | 0.71420 m/s |
Open this example in the calculator and change any input.
Formula
\(CR = \frac{1}{x} \qquad \dot m_c = \frac{\dot m_s}{x} \qquad v_{dc} = \frac{\dot m_c\,v_f}{A_{dc}} \qquad v_{r,in} = \frac{\dot m_c\,v_f}{A_r} \qquad v_{r,out} = \frac{\dot m_c\,(x v_g + (1 - x) v_f)}{A_r}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | steam generated | kg/s |
| \(x\) | riser exit quality | – |
| \(p\) | drum pressure | Pa |
| \(N_{dc}\) | downcomers | – |
| \(d_{dc}\) | downcomer bore | m |
| \(N_r\) | risers | – |
| \(d_r\) | riser bore | m |
| \(CR\) | circulation ratio | – |
| \(\dot m_c\) | circulating flow | kg/s |
| \(v_{dc}\) | downcomer velocity | m/s |
| \(v_{r,in}\) | riser inlet velocity | m/s |
| \(v_{r,out}\) | riser exit mixture velocity | m/s |
| \(v_f, v_g\) | saturated water and steam specific volume (IF97) | m³/kg |
| \(A_{dc}, A_r\) | total downcomer and riser flow areas | m² |
Method and standards
Mass balance of the circuit with saturated water in downcomers and a homogeneous mixture at the riser exit; saturation properties from FireCAD's IAPWS-IF97.
Where it is used
- Checking boiler circulation at proposal stage.
- Downcomer and riser sizing.
- Investigating tube overheating at low circulation.
Common mistakes
- Treating the result as a circulation design: the circulation flow comes from a pressure balance of the circuit.
- Ignoring subcooling at the downcomer inlet.
- Using one quality for all circuits.
Assumptions and limits
- Saturated water in downcomers; homogeneous flow (no slip) at the riser exit.
- The circulation ratio is \(1/x\) from the quality you enter, not from a pressure balance of the circuit; the natural circulation driving head calculator checks whether the circuit can deliver it.
- A note appears for downcomer velocities above about 4 m/s.
References
- Definition of circulation ratio; homogeneous two-phase density
- IAPWS R7-97 IF97
Questions and answers
What is the circulation ratio?
Water circulated per kg of steam made, 1/x at the riser exit. At 10 % exit quality a 50 t/h boiler circulates 139 kg/s; in four 250 mm downcomers that is 0.95 m/s.
What circulation ratio is normal?
It falls as pressure rises because the density difference driving circulation shrinks; the boiler maker designs it with margin for each circuit.
Why the riser exit velocity?
The steam expands the flow; the homogeneous model gives 0.71 m/s here, an upper bound since steam slips past the water.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.