FireCADCalc

Boiler Circulation Ratio, Downcomer and Riser Velocity

Circulation ratio and circulating water flow of a natural-circulation boiler from riser exit quality, with downcomer and riser velocities (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 50 t/h, exit quality 10 %, 68 bar(a), 4 downcomers 250 mm, 400 risers 50 mm10 t/h, 15 %, 18 bar(a), 2 x 150 mm, 120 x 44 mm150 t/h, 6 %, 120 bar(a), 6 x 300 mm, 700 x 52 mm

Results

Assumes saturated water in the downcomers and a homogeneous mixture at the riser exit; real slip between phases lowers the mixture velocity.

Circulation ratio (1/x from the quality entered)6.6667
Circulating water flow66,667kg/h
Downcomer water velocity0.61195m/s
Riser inlet velocity0.11853m/s
Riser exit mixture velocity (homogeneous)1.7809m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 t/h, exit quality 10 %, 68 bar(a), 4 downcomers 250 mm, 400 risers 50 mm. The inputs, in the units selected above:

InputValue
Steam generated50,000 kg/h
Steam quality at riser exit10.000 %
Drum pressure (absolute)68.000 bar
Number of downcomers4.0000 -
Downcomer inside diameter250.00 mm
Number of risers (evaporator tubes)400.00 -
Riser inside diameter50.000 mm

Applying the formula below gives:

ResultValue
Circulation ratio (1/x from the quality entered)10.000
Circulating water flow500,000 kg/h
Downcomer water velocity0.95163 m/s
Riser inlet velocity0.23791 m/s
Riser exit mixture velocity (homogeneous)0.71420 m/s

Open this example in the calculator and change any input.

Formula

\(CR = \frac{1}{x} \qquad \dot m_c = \frac{\dot m_s}{x} \qquad v_{dc} = \frac{\dot m_c\,v_f}{A_{dc}} \qquad v_{r,in} = \frac{\dot m_c\,v_f}{A_r} \qquad v_{r,out} = \frac{\dot m_c\,(x v_g + (1 - x) v_f)}{A_r}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) steam generated kg/s
\(x\) riser exit quality –
\(p\) drum pressure Pa
\(N_{dc}\) downcomers –
\(d_{dc}\) downcomer bore m
\(N_r\) risers –
\(d_r\) riser bore m
\(CR\) circulation ratio –
\(\dot m_c\) circulating flow kg/s
\(v_{dc}\) downcomer velocity m/s
\(v_{r,in}\) riser inlet velocity m/s
\(v_{r,out}\) riser exit mixture velocity m/s
\(v_f, v_g\) saturated water and steam specific volume (IF97) m³/kg
\(A_{dc}, A_r\) total downcomer and riser flow areas m²

Method and standards

Mass balance of the circuit with saturated water in downcomers and a homogeneous mixture at the riser exit; saturation properties from FireCAD's IAPWS-IF97.

Where it is used

  • Checking boiler circulation at proposal stage.
  • Downcomer and riser sizing.
  • Investigating tube overheating at low circulation.

Common mistakes

  • Treating the result as a circulation design: the circulation flow comes from a pressure balance of the circuit.
  • Ignoring subcooling at the downcomer inlet.
  • Using one quality for all circuits.

Assumptions and limits

  • Saturated water in downcomers; homogeneous flow (no slip) at the riser exit.
  • The circulation ratio is \(1/x\) from the quality you enter, not from a pressure balance of the circuit; the natural circulation driving head calculator checks whether the circuit can deliver it.
  • A note appears for downcomer velocities above about 4 m/s.

References

  • Definition of circulation ratio; homogeneous two-phase density
  • IAPWS R7-97 IF97

Questions and answers

What is the circulation ratio?

Water circulated per kg of steam made, 1/x at the riser exit. At 10 % exit quality a 50 t/h boiler circulates 139 kg/s; in four 250 mm downcomers that is 0.95 m/s.

What circulation ratio is normal?

It falls as pressure rises because the density difference driving circulation shrinks; the boiler maker designs it with margin for each circuit.

Why the riser exit velocity?

The steam expands the flow; the homogeneous model gives 0.71 m/s here, an upper bound since steam slips past the water.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.