Downcomer Sizing from Circulation Ratio

Circulating water flow from steam flow and circulation ratio, the downcomer area and bore for an allowed water velocity (IF97 density), and the riser exit quality.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 60 t/h, CR 15High pressure

Results

Keep downcomers unheated and free of steam: entrained steam lowers the circulation head.

Circulating water1,200.0t/h
Saturated water density671.80kg/m³
Total downcomer area0.16539m²
Bore of each downcomer187.34mm
Riser exit quality 1/CR12.500%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 t/h, CR 15. The inputs, in the units selected above:

InputValue
Steam generated60.000 t/h
Circulation ratio (water / steam)15.000 -
Drum pressure (absolute)46.000 bar
Allowed downcomer velocity2.5000 m/s
Number of downcomers4.0000 -

Applying the formula below gives:

ResultValue
Circulating water900.00 t/h
Saturated water density785.52 kg/m³
Total downcomer area0.12730 m²
Bore of each downcomer201.30 mm
Riser exit quality 1/CR6.6667 %

Open this example in the calculator and change any input.

Formula

\(\dot m_w = CR\,\dot m_s, \quad A = \frac{\dot m_w}{\rho_l v}, \quad d = \sqrt{\frac{4A}{n\pi}}, \quad x_e = \frac{1}{CR}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) Steam generated kg/s
\(CR\) Circulation ratio (water / steam) -
\(p_d\) Drum pressure (absolute) Pa
\(v\) Allowed downcomer velocity m/s
\(n\) Number of downcomers -
\(\dot m_w\) Circulating water kg/s
\(\rho_l\) Saturated water density kg/m³
\(A\) Total downcomer area m²
\(d\) Bore of each downcomer m
\(x_e\) Riser exit quality 1/CR -

Method and standards

Mass balance: the water circulated is the circulation ratio times the steam made; continuity at the allowed velocity with the IAPWS-IF97 saturated water density gives the area, split equally over the downcomers.

Where it is used

  • Drum boiler circulation design.

Common mistakes

  • Steam flow counted as water.

Assumptions and limits

  • Saturated downcomer water. Feedwater mixed in the drum leaves the downcomer water slightly subcooled and denser, so the area needed is a little smaller.

References

  • Mass balance ṁ_w = CR ṁ_s; continuity with IAPWS-IF97 saturated density

Questions and answers

What circulation ratio?

Low-pressure industrial boilers run high ratios (15–30); high-pressure boilers lower ones.

Why a velocity limit?

Too fast draws steam bubbles from the drum into the downcomer and raises losses.

Exit quality?

The inverse of the circulation ratio: 15 gives about 6.7 % steam by mass at the riser top.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.