Worked example
Example: 60 t/h, CR 15. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam generated | 60.000 t/h |
| Circulation ratio (water / steam) | 15.000 - |
| Drum pressure (absolute) | 46.000 bar |
| Allowed downcomer velocity | 2.5000 m/s |
| Number of downcomers | 4.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Circulating water | 900.00 t/h |
| Saturated water density | 785.52 kg/m³ |
| Total downcomer area | 0.12730 m² |
| Bore of each downcomer | 201.30 mm |
| Riser exit quality 1/CR | 6.6667 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_w = CR\,\dot m_s, \quad A = \frac{\dot m_w}{\rho_l v}, \quad d = \sqrt{\frac{4A}{n\pi}}, \quad x_e = \frac{1}{CR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_s\) | Steam generated | kg/s |
| \(CR\) | Circulation ratio (water / steam) | - |
| \(p_d\) | Drum pressure (absolute) | Pa |
| \(v\) | Allowed downcomer velocity | m/s |
| \(n\) | Number of downcomers | - |
| \(\dot m_w\) | Circulating water | kg/s |
| \(\rho_l\) | Saturated water density | kg/m³ |
| \(A\) | Total downcomer area | m² |
| \(d\) | Bore of each downcomer | m |
| \(x_e\) | Riser exit quality 1/CR | - |
Method and standards
Mass balance: the water circulated is the circulation ratio times the steam made; continuity at the allowed velocity with the IAPWS-IF97 saturated water density gives the area, split equally over the downcomers.
Where it is used
- Drum boiler circulation design.
Common mistakes
- Steam flow counted as water.
Assumptions and limits
- Saturated downcomer water. Feedwater mixed in the drum leaves the downcomer water slightly subcooled and denser, so the area needed is a little smaller.
References
- Mass balance ṁ_w = CR ṁ_s; continuity with IAPWS-IF97 saturated density
Questions and answers
What circulation ratio?
Low-pressure industrial boilers run high ratios (15–30); high-pressure boilers lower ones.
Why a velocity limit?
Too fast draws steam bubbles from the drum into the downcomer and raises losses.
Exit quality?
The inverse of the circulation ratio: 15 gives about 6.7 % steam by mass at the riser top.