Boiler Water Content (Drum, Tubes, Headers)

Water volume and mass in a water-tube boiler from the drum at its water level, the tubes and the headers, with saturated water density (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: Bi-drum 50 t/h: drum 1.5 m x 9 m, water 0.75 m; 600 tubes 57 mm ID x 12 m; 8 headers 250 mm x 6 mSmall water-tube: drum 1.0 m x 5 m, water 0.45 m; 200 x 44 mm x 6 m; 4 x 200 mm x 4 mDrum only: 1.2 m x 6 m, water 0.7 m

Steam drum (cylindrical part)

Tubes (full of water)

Headers (full of water)

Results

Dished drum ends, downcomers and economiser are not included unless entered as tubes or headers. Cold water for a hydraulic test is denser: use the cold density for that.

Total water volume28.681m³
Water mass at working pressure (all tubes full of saturated water)21.423t
Water in the drum7.9522m³
Water in the tubes18.373m³
Water in the headers2.3562m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Bi-drum 50 t/h: drum 1.5 m x 9 m, water 0.75 m; 600 tubes 57 mm ID x 12 m; 8 headers 250 mm x 6 m. The inputs, in the units selected above:

InputValue
Working pressure (absolute)66.000 bar
Drum inside diameter1.5000 m
Drum length9.0000 m
Water level above the drum bottom0.75000 m
Number of tubes600.00 -
Tube inside diameter57.000 mm
Mean tube length12.000 m
Number of headers8.0000 -
Header inside diameter250.00 mm
Header length6.0000 m

Applying the formula below gives:

ResultValue
Total water volume28.681 m³
Water mass at working pressure (all tubes full of saturated water)21.423 t
Water in the drum7.9522 m³
Water in the tubes18.373 m³
Water in the headers2.3562 m³

Open this example in the calculator and change any input.

Formula

\(V_d = L_d\left[R^2\cos^{-1}\frac{R - h}{R} - (R - h)\sqrt{2Rh - h^2}\right] \qquad V_t = n_t\frac{\pi d_t^2}{4} l_t \qquad V_h = n_h\frac{\pi d_h^2}{4} l_h \qquad M_w = \rho_f\,V\)

Variables

Symbol Meaning SI unit
\(p\) working pressure Pa
\(D\) drum inside diameter m
\(R\) drum radius, D/2 m
\(L_d\) drum length m
\(h\) water level above drum bottom m
\(n_t\) tubes –
\(d_t\) tube bore m
\(l_t\) tube length m
\(n_h\) headers –
\(d_h\) header bore m
\(l_h\) header length m
\(V\) total water volume m³
\(M_w\) water mass kg
\(V_d\) drum water m³
\(V_t\) tube water m³
\(V_h\) header water m³
\(\rho_f\) saturated water density (IF97) kg/m³

Method and standards

Circular segment for the drum, full cylinders for tubes and headers; saturated water density from FireCAD's IAPWS-IF97.

Where it is used

  • Chemical cleaning and boil-out quantities.
  • Start-up and flash calculations.
  • Support and foundation loads.

Common mistakes

  • Forgetting downcomers, economiser and lower drum.
  • Using cold density at working pressure.
  • Ignoring the steam bubbles in risers, which reduce the water mass in operation.

Assumptions and limits

  • Drum without dished ends; tubes and headers full of saturated water. In operation the risers carry steam, so the operating water mass is lower than shown; the figure is the flooded-to-level content.

References

  • Circular segment geometry
  • IAPWS R7-97 IF97

Questions and answers

How much water is in a boiler?

A bi-drum boiler with a 1.5 × 9 m drum half full, 600 tubes of 57 mm bore and 12 m length, and eight 250 mm headers holds 28.7 m³: 21.4 t at 66 bar(a).

Why do I need it?

For chemical cleaning and dosing, start-up heat, flash on pressure drop, and the weight on the supports.

Is the water mass the same cold?

No: cold water is denser, so a flooded boiler for a hydraulic test holds more mass than this.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.