FireCADCalc

Boiling-Point Elevation of Juice and Syrup

Boiling-point elevation of juice or syrup from brix and pressure (Hugot, with vacuum correction), the high-purity rule 2B/(100 − B) and the boiling temperature.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Syrup 65 brix at 16 kPaJuice 20 brix at 200 kPaSyrup 60 brix at 30 kPa

Results

Hugot's formula is for pure sucrose solutions; impurities raise the elevation a little. Add the hydrostatic rise for the temperature in the tubes.

Vacuum below the 76 cmHg standard barometer0mmHg
Boiling-point elevation (Hugot)0.29904K
High-purity rule 2B/(100 − B)0.50000K
Water saturation temperature at p120.21°C
Boiling temperature of the juice120.51°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Syrup 65 brix at 16 kPa. The inputs, in the units selected above:

InputValue
Brix65.000 %
Absolute pressure over the liquid16.000 kPa

Applying the formula below gives:

ResultValue
Vacuum below the 76 cmHg standard barometer639.99 mmHg
Boiling-point elevation (Hugot)3.1617 K
High-purity rule 2B/(100 − B)3.7143 K
Water saturation temperature at p55.314 °C
Boiling temperature of the juice58.476 °C

Open this example in the calculator and change any input.

Formula

\(e = 0.025\,\frac{B(30 + B)}{103.6 - B}\left(1 - \frac{0.54h}{229 - h}\right), \quad e_2 = \frac{2B}{100 - B} \;[^\circ C;\ B\ \%;\ h\ \mathrm{cmHg\ vacuum}]\)

\(T_b = T_s(p) + e\)

Variables

Symbol Meaning SI unit
\(B\) Brix -
\(p\) Absolute pressure over the liquid Pa
\(h\) Vacuum below the 76 cmHg (101.325 kPa) standard barometer Pa
\(e\) Boiling-point elevation (Hugot) K
\(e_2\) High-purity rule 2B/(100 − B) K
\(T_s\) Water saturation temperature at p K
\(T_b\) Boiling temperature of the juice K

Method and standards

Hugot's empirical formulae (Handbook of Cane Sugar Engineering, 3rd ed.): the high-purity rule e₂ = 2B/(100 − B) on p. 497 and the formula with the vacuum correction on pp. 497–499, where h is the vacuum in cmHg. Hugot does not name the barometer; his Table 32.2 is at 760 mm and the Othmer–Silvis chart (Fig. 32.1) puts 0 cm vacuum at 100 °C, so the vacuum is taken from the 76 cmHg standard barometer. Water saturation temperature from IAPWS-IF97.

Where it is used

  • Evaporator and pan calculations.
  • Setting syrup brix against vacuum.

Common mistakes

  • Using brix as a fraction in the formula.
  • Forgetting the vacuum correction.

Assumptions and limits

  • Pure sucrose basis; brix up to about 90. Impurities raise the elevation, so for low-purity syrups and molasses it is underestimated.
  • In the formula h is the vacuum in cmHg (1 cmHg = 1333.224 Pa) below 76 cmHg, whatever the local barometer; enter the absolute pressure over the liquid.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 32
  • boiling-point elevation: high-purity rule p. 497
  • vacuum formula pp. 497–499 (unnumbered)
  • Water saturation temperature from IAPWS-IF97

Questions and answers

Why does vacuum lower the elevation?

Boiling-point elevation scales roughly with the absolute temperature squared; at lower pressure it is smaller.

Which formula for syrup?

Hugot's formula with the vacuum term; the 2B/(100 − B) rule is a quick check for high-purity products.

Is this the whole loss of temperature?

No: the hydrostatic head in the tubes adds a rise of its own, often larger in the last effect.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.