Worked example
Example: 3.3 t/h distillate, R 3.5. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Distillate (product draw) | 3,300.0 kg/h |
| Reflux ratio L/D | 3.5000 - |
| Latent heat of the overhead vapour | 950.00 kJ/kg |
| Cooling-water rise | 8.0000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Overhead vapour | 14,850 kg/h |
| Condenser duty | 3,918.8 kW |
| Cooling water | 421.19 t/h |
Open this example in the calculator and change any input.
Formula
\(V = D (R + 1), \quad \dot Q_c = V \lambda, \quad \dot m_w = \frac{\dot Q_c}{c_w \Delta T_w}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Distillate (product draw) | kg/s |
| \(R\) | Reflux ratio L/D | - |
| \(\lambda\) | Latent heat of the overhead vapour | J/kg |
| \(\Delta T_w\) | Cooling-water rise | K |
| \(V\) | Overhead vapour | kg/s |
| \(\dot Q_c\) | Condenser duty | W |
| \(\dot m_w\) | Cooling water | kg/s |
| \(c_w\) | Cooling-water specific heat, 4 186.8 | J/(kg·K) |
Method and standards
Balance.
Where it is used
- Column condenser sizing.
- Energy integration studies.
Common mistakes
- Reflux ratio as L/V.
Assumptions and limits
- Total condenser.
References
- Overhead balance V = D (R + 1); Q = V λ (McCabe–Thiele constant molal overflow)
Questions and answers
Why does reflux cost so much?
Every kg of reflux is vapour that was boiled and must be condensed.
Latent heat of ethanol–water vapour?
Between pure ethanol (about 0.85 MJ/kg) and water (2.26 MJ/kg); near the azeotrope about 0.9–1.0.
Reboiler duty?
Roughly the condenser duty plus heat to bring feed to its boiling point.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.