FireCADCalc

Ethanol–Water Isothermal Flash at 1 atm

Vapour fraction and liquid and vapour strengths when an ethanol–water feed is heated to a temperature between its bubble and dew points near 1 atm (Wilson).

Distillery and ethanolIAPWS-IF97 (water and steam)

Inputs

Examples: 30 % vol feed at 90 °C0.2 mole fraction at 88 °C

Model fitted at 1 atm; use 0.9–1.2 atm.

Results

Feed mole fraction20.000%
Liquid mole fraction7.4552%
Vapour mole fraction39.427%
Vapour fraction (molar)39.237%
Liquid strength21.047%
Condensed vapour strength70.078%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 % vol feed at 90 °C. The inputs, in the units selected above:

InputValue
Feed strength entered as% vol at 20 °C
Feed strength30.000 %
Flash temperature90.000 °C
Pressure101.33 kPa

Applying the formula below gives:

ResultValue
Feed mole fraction11.318 %
Liquid mole fraction5.1689 %
Vapour mole fraction33.637 %
Vapour fraction (molar)21.602 %
Liquid strength15.172 %
Condensed vapour strength64.318 %

Open this example in the calculator and change any input.

Formula

\(T_b(x_1) = T, \quad y_1 = y^*(x_1), \quad \frac{V}{F} = \frac{z_1 - x_1}{y_1 - x_1}\)

Variables

Symbol Meaning SI unit
\(\text{basis}\) Feed strength entered as -
\(s_F\) Feed strength -
\(T\) Flash temperature K
\(P\) Pressure Pa
\(z_1\) Feed mole fraction -
\(x_1\) Liquid mole fraction -
\(y_1\) Vapour mole fraction -
\(V/F\) Vapour fraction (molar) -
\(q_x\) Liquid strength -
\(q_y\) Condensed vapour strength -

Method and standards

Equilibrium at the flash temperature with the lever rule.

Where it is used

  • Flash drums and single-stage stills.
  • Teaching T–x–y diagrams.

Common mistakes

  • Treating a mass fraction as molar.
  • Flashing above the dew point.

Assumptions and limits

  • Wilson energies fitted at 1 atm; 0.9–1.2 atm only.
  • Binary ethanol–water; congeners and dissolved solids ignored.

References

  • Ethanol–water VLE at about 1 atm: Wilson equation (Perry's Chemical Engineers' Handbook, 9th ed., sec. 4) with energies 399 and 933 cal/mol fitted to FireCAD ethanol–water x–y–T data at 101.325 kPa; ethanol vapour pressure Perry's 9th ed. Table 2-8; water IAPWS-IF97
  • Checked against Gmehling and Onken
  • DECHEMA Chemistry Data Series vol. I/1
  • as quoted in Perry's 9th ed. sec. 13 (simple batch distillation example)

Questions and answers

How is the split found?

At the flash temperature the liquid and vapour lie on the bubble and dew curves; the lever rule gives the vapour fraction.

Why must the temperature be between bubble and dew points?

Outside that band the feed is wholly liquid or wholly vapour.

Is the vapour fraction molar?

Yes; convert with molar masses for kilograms.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.