Alcohol Lost in Spent Wash and Lees

Absolute alcohol lost per day in spent wash and spent lees from their flows and alcohol contents, and the loss as a share of production.

Distillery and ethanol

Inputs

Examples: TypicalColumn trouble

Results

Spent wash should carry only traces of alcohol; a rise points to analyser column trouble.

Lost in spent wash37.500L/h
Lost in spent lees2.5000L/h
Loss as share of the alcohol produced1.0667%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Typical. The inputs, in the units selected above:

InputValue
Spent wash1,000.0 m³/d
Alcohol in spent wash (% v/v)0.020000 %
Spent lees150.00 m³/d
Alcohol in spent lees (% v/v)0.010000 %
Alcohol produced (absolute)100.00 kL/d

Applying the formula below gives:

ResultValue
Lost in spent wash8.3333 L/h
Lost in spent lees0.62500 L/h
Loss as share of the alcohol produced0.21500 %

Open this example in the calculator and change any input.

Formula

\(L = \dot V s, \quad \frac{L_w + L_l}{\dot V_e}\)

Variables

Symbol Meaning SI unit
\(\dot V_{sw}\) Spent wash m³/s
\(s_{sw}\) Alcohol in spent wash (% v/v) -
\(\dot V_l\) Spent lees m³/s
\(s_l\) Alcohol in spent lees (% v/v) -
\(\dot V_e\) Alcohol produced (absolute) m³/s
\(L_w\) Lost in spent wash m³/s
\(L_l\) Lost in spent lees m³/s
\(L/\dot V_e\) Loss as share of the alcohol produced -

Method and standards

Loss = flow × alcohol content for each stream; the share is the total loss over the absolute alcohol produced (not over production plus loss).

Where it is used

  • Distillation efficiency checks.

Common mistakes

  • ppm and % v/v mixed.

Assumptions and limits

  • Daily averages.
  • Flows and % v/v at the same reference temperature (normally 20 °C) as the production figure.

References

  • Loss = flow × alcohol content

Questions and answers

Acceptable loss?

Well under 0.05 % v/v in spent wash; check your column's guarantee.

Where else is alcohol lost?

Vent gases, CO₂ scrubber water, leaks and evaporation from tanks.

How is it measured?

Distil a sample and measure the distillate's density.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.