Worked example
Example: Typical. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Spent wash | 1,000.0 m³/d |
| Alcohol in spent wash (% v/v) | 0.020000 % |
| Spent lees | 150.00 m³/d |
| Alcohol in spent lees (% v/v) | 0.010000 % |
| Alcohol produced (absolute) | 100.00 kL/d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Lost in spent wash | 8.3333 L/h |
| Lost in spent lees | 0.62500 L/h |
| Loss as share of the alcohol produced | 0.21500 % |
Open this example in the calculator and change any input.
Formula
\(L = \dot V s, \quad \frac{L_w + L_l}{\dot V_e}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V_{sw}\) | Spent wash | m³/s |
| \(s_{sw}\) | Alcohol in spent wash (% v/v) | - |
| \(\dot V_l\) | Spent lees | m³/s |
| \(s_l\) | Alcohol in spent lees (% v/v) | - |
| \(\dot V_e\) | Alcohol produced (absolute) | m³/s |
| \(L_w\) | Lost in spent wash | m³/s |
| \(L_l\) | Lost in spent lees | m³/s |
| \(L/\dot V_e\) | Loss as share of the alcohol produced | - |
Method and standards
Loss = flow × alcohol content for each stream; the share is the total loss over the absolute alcohol produced (not over production plus loss).
Where it is used
- Distillation efficiency checks.
Common mistakes
- ppm and % v/v mixed.
Assumptions and limits
- Daily averages.
- Flows and % v/v at the same reference temperature (normally 20 °C) as the production figure.
References
- Loss = flow × alcohol content
Questions and answers
Acceptable loss?
Well under 0.05 % v/v in spent wash; check your column's guarantee.
Where else is alcohol lost?
Vent gases, CO₂ scrubber water, leaks and evaporation from tanks.
How is it measured?
Distil a sample and measure the distillate's density.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.