FireCADCalc

Sulphur Burner: Air, SO₂ Strength and Tray Area

Sulphur burnt for a dose, the air for an SO₂ strength in the gas, excess air, burner tray area and heat released (Hugot ch. 25, from stoichiometry).

Sugar mill and cogeneration

Inputs

Examples: 100 TCH, 14 % SO2Juice and syrup, 12 %

Hugot: 0.3–0.45 kg/t cane for juice; about 0.9 for juice and syrup.
Hugot: 12–16 %, about 14 %; 21 % is the theoretical maximum.
Hugot: 20–25 kg/(m²·h), up to 35.

Results

Burning sulphur replaces each O₂ molecule by one SO₂, so the gas volume stays that of the air; dry the air to limit SO₃.

Sulphur burnt135.00kg/h
Air786.52Nm³/h
Air1,016.4kg/h
Excess air74.583%
Burner tray area5.4000m²
Heat released (2217 kcal/kg S)348.08kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 TCH, 14 % SO2. The inputs, in the units selected above:

InputValue
Crushing rate100.00 t/h
Sulphur per tonne cane0.40000 kg/t
SO₂ in the gas (by volume)14.000 %
Tray loading22.500 kg/(m²·h)

Applying the formula below gives:

ResultValue
Sulphur burnt40.000 kg/h
Air199.75 Nm³/h
Air258.14 kg/h
Excess air49.643 %
Burner tray area1.7778 m²
Heat released (2217 kcal/kg S)103.13 kW

Open this example in the calculator and change any input.

Formula

\(\dot m_S = d_S A, \quad \dot n_{air} = \frac{\dot m_S/M_S}{y_{SO_2}}, \quad \lambda - 1 = \frac{0.2095}{y_{SO_2}} - 1, \quad A_t = \frac{\dot m_S}{g}\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(d_S\) Sulphur per tonne cane kg/kg
\(y_{SO_2}\) SO₂ in the gas (by volume) -
\(g\) Tray loading kg/(m²·s)
\(\dot m_S\) Sulphur burnt kg/s
\(\dot V_a\) Air Nm³/s
\(\dot m_a\) Air kg/s
\(\lambda - 1\) Excess air -
\(A_t\) Burner tray area m²
\(\dot Q\) Heat released (2217 kcal/kg S) W

Method and standards

Stoichiometry of sulphur combustion.

Where it is used

  • Sizing sulphur burners and compressors.
  • Checking sulphitation gas strength.

Common mistakes

  • Using SO₂ mass % for volume %.
  • Confusing air at 0 °C with air at the compressor.

Assumptions and limits

  • Complete combustion to SO₂; sublimed sulphur and burner efficiency are not included.
  • Air is dry, in normal m³ at 0 °C and 1 atm, not air at the compressor conditions.
  • The heat of combustion 2 217 kcal/kg S is used as a fixed figure on this page.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 25
  • sulphur furnaces
  • pp. 407–410
  • Stoichiometry S + O₂ → SO₂; air O₂ 20.95 % by volume; molar volume at 0 °C
  • 1 atm

Questions and answers

Why not burn with the theoretical air?

The gas would approach 21 % SO₂ and the furnace would overheat and sublime sulphur; 12–16 % is usual.

Why dry the air?

Moisture favours SO₃ and sulphuric acid, which corrode and waste sulphur.

Hugot's air figure?

About 6 m³ of air per kg of sulphur gives roughly 12 % SO₂.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.