FireCADCalc

Milk of Lime: Baumé, Density and Dose

Specific gravity and density of milk of lime from degrees Baumé, CaO needed per hour from the dose per tonne of cane, and the milk-of-lime flow.

Sugar mill and cogeneration

Inputs

Examples: 15 °Bé, 0.9 kg/t10 °Bé, 1.2 kg/t

From your lab or the lime table for the Baumé reading.
Hugot ch. 24: 0.5–0.8 kg CaO per t cane for raw sugar; hot liming takes 15–20 % less.

Results

Specific gravity 145/(145 − °Bé)1.1154
Density (water at 60 °F, 999.0 kg/m³)1,114.3kg/m³
CaO needed225.00kg/h
Milk-of-lime flow1,500.0L/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 15 °Bé, 0.9 kg/t. The inputs, in the units selected above:

InputValue
Baumé (heavy-liquid scale)15.000 -
CaO content of the milk of lime150.00 g/L
Lime dose as CaO per tonne cane0.90000 kg/t
Crushing rate250.00 t/h

Applying the formula below gives:

ResultValue
Specific gravity 145/(145 − °Bé)1.1154
Density (water at 60 °F, 999.0 kg/m³)1,114.3 kg/m³
CaO needed225.00 kg/h
Milk-of-lime flow1,500.0 L/h

Open this example in the calculator and change any input.

Formula

\(SG = \frac{145}{145 - {}^\circ\!B\acute e}, \quad \dot V = \frac{d\,C}{c_{CaO}}\)

Variables

Symbol Meaning SI unit
\(°Bé\) Baumé (heavy-liquid scale) -
\(c_{CaO}\) CaO content of the milk of lime kg/m³
\(d\) Lime dose as CaO per tonne cane kg/kg
\(C\) Crushing rate kg/s
\(SG\) Specific gravity 145/(145 − °Bé) -
\(\rho\) Density (water 999.0 kg/m³) kg/m³
\(\dot m_{CaO}\) CaO needed kg/s
\(\dot V\) Milk-of-lime flow m³/s

Method and standards

Baumé scale; mass balance.

Where it is used

  • Lime station sizing.
  • Lime consumption reports.

Common mistakes

  • Light-liquid Baumé scale used.

Assumptions and limits

  • Uniform suspension.
  • The CaO content is your own figure; it is not checked against the Baumé reading, and the specific gravity and density do not enter the dose. Take the CaO for the reading from your laboratory's lime table.
  • Density = SG × 999.0 kg/m³, the density of water at 60 °F (15.6 °C), the reference of the US Baumé scale.

References

  • Baumé heavy-liquid scale SG = 145/(145 − °Bé) (US standard modulus 145)
  • Mass balance for the lime dose

Questions and answers

Why is CaO an input?

The CaO content for a Baumé reading depends on lime quality and temperature; use your lab table.

Which Baumé scale?

The heavy-liquid scale with modulus 145.

Dose control?

Liming is controlled on juice pH; this gives the average consumption.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.