Worked example
Example: 15 °Bé, 0.9 kg/t. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Baumé (heavy-liquid scale) | 15.000 - |
| CaO content of the milk of lime | 150.00 g/L |
| Lime dose as CaO per tonne cane | 0.90000 kg/t |
| Crushing rate | 250.00 t/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific gravity 145/(145 − °Bé) | 1.1154 |
| Density (water at 60 °F, 999.0 kg/m³) | 1,114.3 kg/m³ |
| CaO needed | 225.00 kg/h |
| Milk-of-lime flow | 1,500.0 L/h |
Open this example in the calculator and change any input.
Formula
\(SG = \frac{145}{145 - {}^\circ\!B\acute e}, \quad \dot V = \frac{d\,C}{c_{CaO}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(°Bé\) | Baumé (heavy-liquid scale) | - |
| \(c_{CaO}\) | CaO content of the milk of lime | kg/m³ |
| \(d\) | Lime dose as CaO per tonne cane | kg/kg |
| \(C\) | Crushing rate | kg/s |
| \(SG\) | Specific gravity 145/(145 − °Bé) | - |
| \(\rho\) | Density (water 999.0 kg/m³) | kg/m³ |
| \(\dot m_{CaO}\) | CaO needed | kg/s |
| \(\dot V\) | Milk-of-lime flow | m³/s |
Method and standards
Baumé scale; mass balance.
Where it is used
- Lime station sizing.
- Lime consumption reports.
Common mistakes
- Light-liquid Baumé scale used.
Assumptions and limits
- Uniform suspension.
- The CaO content is your own figure; it is not checked against the Baumé reading, and the specific gravity and density do not enter the dose. Take the CaO for the reading from your laboratory's lime table.
- Density = SG × 999.0 kg/m³, the density of water at 60 °F (15.6 °C), the reference of the US Baumé scale.
References
- Baumé heavy-liquid scale SG = 145/(145 − °Bé) (US standard modulus 145)
- Mass balance for the lime dose
Questions and answers
Why is CaO an input?
The CaO content for a Baumé reading depends on lime quality and temperature; use your lab table.
Which Baumé scale?
The heavy-liquid scale with modulus 145.
Dose control?
Liming is controlled on juice pH; this gives the average consumption.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.