FireCADCalc

Juice Heater Tube Velocity and Reynolds Number

Juice velocity and Reynolds number in the tubes of a multi-pass juice heater from the flow, juice density and viscosity, tube bore and tubes per pass.

Sugar mill and cogeneration

Inputs

Examples: 41 mm tubes, 30 per passSyrup-side heater

Results

Juice velocity 1.15 m/s is outside the 1.5–2 m/s usual for juice heaters (Hugot): below it scale builds faster, above it the pressure drop rises.

Juice velocity in the tubes1.1549m/s
Reynolds number16,842

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 41 mm tubes, 30 per pass. The inputs, in the units selected above:

InputValue
Juice flow260.00 t/h
Juice density1,060.0 kg/m³
Juice viscosity6.0000e-04 Pa·s
Tube inside diameter41.000 mm
Tubes per pass30.000 -

Applying the formula below gives:

ResultValue
Juice velocity in the tubes1.7202 m/s
Reynolds number124,602

Open this example in the calculator and change any input.

Formula

\(v = \frac{\dot m_j}{\rho\,n\,\pi d_i^2/4}, \quad Re = \frac{\rho v d_i}{\mu}\)

Variables

Symbol Meaning SI unit
\(\dot m_j\) Juice flow kg/s
\(\rho\) Juice density kg/m³
\(\mu\) Juice viscosity Pa·s
\(d_i\) Tube inside diameter m
\(n\) Tubes per pass -
\(v\) Juice velocity in the tubes m/s
\(Re\) Reynolds number -

Method and standards

Continuity.

Where it is used

  • Juice heater pass arrangement.

Common mistakes

  • Counting all tubes instead of tubes per pass.

Assumptions and limits

  • Full tubes.
  • A note compares the velocity with the usual 1.5–2 m/s, the same band as the juice heater coefficient and pressure drop calculators.

References

  • Continuity v = ṁ/(ρ n π d²/4); Re = ρ v d/μ

Questions and answers

Why does velocity matter?

Higher velocity raises the film coefficient and slows scale, at the cost of pressure drop.

How to raise it?

Fewer tubes per pass, so more passes for the same surface.

Viscosity of juice?

Close to water at heater temperatures; syrup is far more viscous.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.