FireCADCalc

Juice Heater Duty and Steam Consumption

Heat to raise mixed or clear juice to temperature and the exhaust or vapour steam it condenses, with IF97 latent heat at the steam pressure.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Raw juice 35 to 103 °CClear juice on vapour

About 3.9 kJ/kg K for mixed juice; lower for syrup.

Results

Condensate leaves saturated; vapour from an evaporator effect saves live exhaust steam.

Heater duty19,153kW
Steam saturation temperature120.21°C
Latent heat at steam pressure2,201.6kJ/kg
Steam condensed31.946t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Raw juice 35 to 103 °C. The inputs, in the units selected above:

InputValue
Juice flow260.00 t/h
Juice specific heat3.9000 kJ/(kg·K)
Juice in35.000 °C
Juice out103.00 °C
Heating steam or vapour pressure (absolute)2.0000 bar
Heat losses (share of duty)2.0000 %

Applying the formula below gives:

ResultValue
Heater duty19,153 kW
Steam saturation temperature120.21 °C
Latent heat at steam pressure2,201.6 kJ/kg
Steam condensed31.946 t/h

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_j c_p (T_2 - T_1), \quad T_s = T_{sat}(p_s), \quad h_{fg} = h_g(p_s) - h_f(p_s), \quad \dot m_s = \frac{\dot Q (1 + k_l)}{h_{fg}(p_s)}\)

Variables

Symbol Meaning SI unit
\(\dot m_j\) Juice flow kg/s
\(c_p\) Juice specific heat J/(kg·K)
\(T_1\) Juice in K
\(T_2\) Juice out K
\(p_s\) Heating steam or vapour pressure (absolute) Pa
\(k_l\) Heat losses (share of duty) -
\(\dot Q\) Heater duty W
\(T_s\) Steam saturation temperature K
\(h_{fg}\) Latent heat at steam pressure J/kg
\(\dot m_s\) Steam condensed kg/s

Method and standards

Energy balance.

Where it is used

  • Raw and clear juice heaters.
  • Steam balance of the process house.

Common mistakes

  • Gauge pressure for saturation.
  • Ignoring heat losses.

Assumptions and limits

  • Saturated condensate; saturated steam (no superheat credit, no condensate subcooling).
  • The steam pressure is absolute: a gauge reading entered as absolute gives a saturation temperature about 20 K too low at 1 bar(g).
  • c_p is your figure; the juice specific heat calculator gives it from brix and purity.

References

  • Energy balance with IAPWS-IF97 latent heat; Hugot
  • Handbook of Cane Sugar Engineering (juice heating)

Questions and answers

Why heat juice with vapour?

Vapour bled from an evaporator effect is cheaper than exhaust (Rillieux's principle).

What specific heat?

Mixed juice is close to water less a little for the dissolved solids, about 3.9 kJ/kg K.

Condensate sub-cooled?

Then each kg of steam gives slightly more heat; this calculator takes saturated condensate.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.