FireCADCalc

Juice Heater Coefficient (Hugot and Others)

Heat-transfer coefficient of a tubular juice heater by Hugot's formula (eqn 30.11) with his scaling factor (30.18), and by Hausbrand's and the Australian formulae.

Sugar mill and cogeneration

Inputs

Examples: Hugot: 115 °C, 1.8 m/s, clean92 °C vapour after 6 days

Hugot: 6; up to 8 with little scale; 5 or 7 with his scale terms.
Hugot: 6 favourable, 4 average, 3 unfavourable juice.

Results

Juice velocity 2.0 m/s is outside the usual 1.5–2 m/s: below it scale builds faster, above it pressure drop rises.

Hugot's formulae are in kcal/(m²·h·°C) on the inside tube area; converted to W/(m²·K) here.

Hugot, clean tubes709.59W/(m²·K)
Hugot, after J days448.78W/(m²·K)
Hausbrand 750∛(V + 0.007)1,107.5W/(m²·K)
Australian 900√V1,495.0W/(m²·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot: 115 °C, 1.8 m/s, clean. The inputs, in the units selected above:

InputValue
Heating vapour temperature115.00 °C
Juice velocity in the tubes1.8000 m/s
Hugot coefficient6.0000 -
Scaling factor A6.0000 -
Days since cleaning0 d

Applying the formula below gives:

ResultValue
Hugot, clean tubes802.47 W/(m²·K)
Hugot, after J days802.47 W/(m²·K)
Hausbrand 750∛(V + 0.007)1,062.4 W/(m²·K)
Australian 900√V1,404.3 W/(m²·K)

Open this example in the calculator and change any input.

Formula

\(k_H = C\,T\left(\frac{U}{1.8}\right)^{0.8}, \quad k = k_H\sqrt{\frac{A_s}{A_s + J}}, \quad k_{Hb} = 750\sqrt[3]{U + 0.007}, \quad k_{Au} = 900\sqrt U \;[\mathrm{kcal/(m^2\,h\,^\circ C)}]\)

Variables

Symbol Meaning SI unit
\(T\) Heating vapour temperature K
\(U\) Juice velocity in the tubes m/s
\(C\) Hugot coefficient -
\(A_s\) Scaling factor A -
\(J\) Days since cleaning s
\(k_H\) Hugot, clean tubes W/(m²·K)
\(k\) Hugot, after J days W/(m²·K)
\(k_{Hb}\) Hausbrand 750∛(V + 0.007) W/(m²·K)
\(k_{Au}\) Australian 900√V W/(m²·K)

Method and standards

Hugot's empirical heater formulae.

Where it is used

  • Sizing juice heaters.
  • Setting cleaning intervals.

Common mistakes

  • Using outside tube area with Hugot's figures.
  • Taking T in kelvin.

Assumptions and limits

  • Tubular heaters, condensing vapour.
  • In the formulas T is in °C and U in m/s and the results in kcal/(m²·h·°C), although the Variables table gives SI units; the page converts.
  • The velocity ranges over which the three correlations were fitted are not stated; a note appears outside the usual 1.5–2 m/s.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 30
  • eqns 30.8–30.11 and 30.18–30.19
  • pp. 451–455

Questions and answers

Why does the coefficient rise with vapour temperature?

Hotter juice is less viscous, so the juice-side film transfers more heat.

Why 1.8 m/s?

Hugot's reference velocity; coefficients rise with the 0.8 power of velocity.

How fast does scale act?

Hugot's factor √(A/(A + J)): with average juice (A = 4) the coefficient halves in about 12 days.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.