Worked example
Example: Hugot: 115 °C, 1.8 m/s, clean. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heating vapour temperature | 115.00 °C |
| Juice velocity in the tubes | 1.8000 m/s |
| Hugot coefficient | 6.0000 - |
| Scaling factor A | 6.0000 - |
| Days since cleaning | 0 d |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hugot, clean tubes | 802.47 W/(m²·K) |
| Hugot, after J days | 802.47 W/(m²·K) |
| Hausbrand 750∛(V + 0.007) | 1,062.4 W/(m²·K) |
| Australian 900√V | 1,404.3 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(k_H = C\,T\left(\frac{U}{1.8}\right)^{0.8}, \quad k = k_H\sqrt{\frac{A_s}{A_s + J}}, \quad k_{Hb} = 750\sqrt[3]{U + 0.007}, \quad k_{Au} = 900\sqrt U \;[\mathrm{kcal/(m^2\,h\,^\circ C)}]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T\) | Heating vapour temperature | K |
| \(U\) | Juice velocity in the tubes | m/s |
| \(C\) | Hugot coefficient | - |
| \(A_s\) | Scaling factor A | - |
| \(J\) | Days since cleaning | s |
| \(k_H\) | Hugot, clean tubes | W/(m²·K) |
| \(k\) | Hugot, after J days | W/(m²·K) |
| \(k_{Hb}\) | Hausbrand 750∛(V + 0.007) | W/(m²·K) |
| \(k_{Au}\) | Australian 900√V | W/(m²·K) |
Method and standards
Hugot's empirical heater formulae.
Where it is used
- Sizing juice heaters.
- Setting cleaning intervals.
Common mistakes
- Using outside tube area with Hugot's figures.
- Taking T in kelvin.
Assumptions and limits
- Tubular heaters, condensing vapour.
- In the formulas T is in °C and U in m/s and the results in kcal/(m²·h·°C), although the Variables table gives SI units; the page converts.
- The velocity ranges over which the three correlations were fitted are not stated; a note appears outside the usual 1.5–2 m/s.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 30
- eqns 30.8–30.11 and 30.18–30.19
- pp. 451–455
Questions and answers
Why does the coefficient rise with vapour temperature?
Hotter juice is less viscous, so the juice-side film transfers more heat.
Why 1.8 m/s?
Hugot's reference velocity; coefficients rise with the 0.8 power of velocity.
How fast does scale act?
Hugot's factor √(A/(A + J)): with average juice (A = 4) the coefficient halves in about 12 days.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.