FireCADCalc

Juice Flash Tank: Flash Vapour and Temperature

Flash vapour released when heated juice enters a flash tank, from juice temperature and flow, tank pressure, boiling-point elevation and IF97 latent heat.

Sugar mill and cogenerationIAPWS-IF97 (water and steam)

Inputs

Examples: Atmospheric flashClear juice to first body

Results

Flashing removes air and dissolved gases so flocs settle in the clarifier.

Juice boiling point in the tank109.59°C
Flash vapour2.3791t/h
Flash vapour share of juice0.93297%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Atmospheric flash. The inputs, in the units selected above:

InputValue
Juice flow260.00 t/h
Juice temperature in105.00 °C
Flash tank pressure (absolute)1.0132 bar
Boiling-point elevation of the juice0.20000 K
Juice specific heat3.9000 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Juice boiling point in the tank100.17 °C
Flash vapour2.1685 t/h
Flash vapour share of juice0.83403 %

Open this example in the calculator and change any input.

Formula

\(T_b = T_{sat}(p) + BPE, \quad x = \frac{c_p (T_j - T_b)}{h_{fg}(p)}\)

Variables

Symbol Meaning SI unit
\(\dot m_j\) Juice flow kg/s
\(T_j\) Juice temperature in K
\(p\) Flash tank pressure (absolute) Pa
\(BPE\) Boiling-point elevation of the juice K
\(c_p\) Juice specific heat J/(kg·K)
\(T_b\) Juice boiling point in the tank K
\(\dot m_v\) Flash vapour kg/s
\(x\) Flash vapour share of juice -

Method and standards

Energy balance.

Where it is used

  • Flash tank sizing.
  • Clarification troubleshooting.

Common mistakes

  • Forgetting BPE at higher brix.

Assumptions and limits

  • Adiabatic flash.
  • Juice specific heat and boiling-point elevation are separate inputs, not linked to brix: take both for your juice (c_p falls as brix rises). The result is proportional to c_p.
  • The latent heat is taken at the water saturation temperature at p rather than at the juice boiling point; the difference is small for BPE below about 1 K.

References

  • Energy balance with IAPWS-IF97 saturation and latent heat; boiling-point elevation as input

Questions and answers

Why flash juice before the clarifier?

Boiling releases air bubbles that would float the mud.

Why heat a few degrees above boiling?

To guarantee flashing even as pressure and BPE vary.

Is the vapour used?

Small flows usually go to a condenser or vent.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.