FireCADCalc

Heater Coefficient Fall with Scale and Cleaning Interval

Fall of a juice heater or evaporator coefficient with time on line by Hugot's law k = k₀√(A/(A + J)) (eqn 30.18), and the days until it reaches a cleaning limit.

Sugar mill and cogeneration

Inputs

Examples: Hugot exampleUnfavourable juice

Hugot: 6 favourable, 4 average, 3 unfavourable.

Results

Hugot's example: k₀ = 1000, A = 6, after 6 days k = 707 kcal/(m²·h·°C).

Coefficient after J days609.09W/(m²·K)
Fraction of the clean coefficient65.465%
Days to the cleaning limit6.4815d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example. The inputs, in the units selected above:

InputValue
Coefficient when clean1,163.0 W/(m²·K)
Juice scaling factor, in days (Hugot's A, not the crushing rate)6.0000 -
Days on line6.0000 d
Coefficient at which to clean581.50 W/(m²·K)

Applying the formula below gives:

ResultValue
Coefficient after J days822.37 W/(m²·K)
Fraction of the clean coefficient70.711 %
Days to the cleaning limit18.000 d

Open this example in the calculator and change any input.

Formula

\(k = k_0\sqrt{\frac{A}{A + J}}, \quad J_c = A\left[\left(\frac{k_0}{k_l}\right)^2 - 1\right]\)

Variables

Symbol Meaning SI unit
\(k_0\) Coefficient when clean W/(m²·K)
\(A\) Juice scaling factor (Hugot's A, not the crushing rate) days
\(J\) Days on line (entered in any time unit, converted to days in the law) s
\(k_l\) Coefficient at which to clean W/(m²·K)
\(k\) Coefficient after J days W/(m²·K)
\(k/k_0\) Fraction of the clean coefficient -
\(J_c\) Days to the cleaning limit s

Method and standards

Hugot's scaling law.

Where it is used

  • Planning heater and evaporator cleaning.
  • Sizing spare heaters.

Common mistakes

  • Mixing days and hours.
  • Using the outside-area coefficient.

Assumptions and limits

  • Steady scaling rate.
  • In Hugot's law A and J are both in days: A is entered as a number of days and J is converted to days. Here A is Hugot's scaling factor, not the crushing rate A used elsewhere on the site.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 30
  • eqns 30.15–30.18
  • pp. 453–454

Questions and answers

Why the square root?

Hugot fits scale growing so that the resistance rises linearly with time, giving k ∝ 1/√(1 + J/A).

How to find A?

From two coefficient readings on the same heater at different days.

Hours instead of days?

Use 24A in place of A.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.