Worked example
Example: Hugot example. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Coefficient when clean | 1,163.0 W/(m²·K) |
| Juice scaling factor, in days (Hugot's A, not the crushing rate) | 6.0000 - |
| Days on line | 6.0000 d |
| Coefficient at which to clean | 581.50 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Coefficient after J days | 822.37 W/(m²·K) |
| Fraction of the clean coefficient | 70.711 % |
| Days to the cleaning limit | 18.000 d |
Open this example in the calculator and change any input.
Formula
\(k = k_0\sqrt{\frac{A}{A + J}}, \quad J_c = A\left[\left(\frac{k_0}{k_l}\right)^2 - 1\right]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k_0\) | Coefficient when clean | W/(m²·K) |
| \(A\) | Juice scaling factor (Hugot's A, not the crushing rate) | days |
| \(J\) | Days on line (entered in any time unit, converted to days in the law) | s |
| \(k_l\) | Coefficient at which to clean | W/(m²·K) |
| \(k\) | Coefficient after J days | W/(m²·K) |
| \(k/k_0\) | Fraction of the clean coefficient | - |
| \(J_c\) | Days to the cleaning limit | s |
Method and standards
Hugot's scaling law.
Where it is used
- Planning heater and evaporator cleaning.
- Sizing spare heaters.
Common mistakes
- Mixing days and hours.
- Using the outside-area coefficient.
Assumptions and limits
- Steady scaling rate.
- In Hugot's law A and J are both in days: A is entered as a number of days and J is converted to days. Here A is Hugot's scaling factor, not the crushing rate A used elsewhere on the site.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 30
- eqns 30.15–30.18
- pp. 453–454
Questions and answers
Why the square root?
Hugot fits scale growing so that the resistance rises linearly with time, giving k ∝ 1/√(1 + J/A).
How to find A?
From two coefficient readings on the same heater at different days.
Hours instead of days?
Use 24A in place of A.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.