Worked example
Example: 250 m3/h, 2.5 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Juice flow | 250.00 m³/h |
| Retention time | 2.5000 h |
| Working depth | 5.0000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Working volume | 625.00 m³ |
| Plan area V/H | 125.00 m² |
| Diameter of one round clarifier | 12.616 m |
Open this example in the calculator and change any input.
Formula
\(V = \dot V t, \quad A = \frac{V}{H}, \quad D = \sqrt{4A/\pi}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot V\) | Juice flow | m³/s |
| \(t\) | Retention time | s |
| \(H\) | Working depth | m |
| \(V\) | Working volume | m³ |
| \(A\) | Plan area V/H (single compartment) | m² |
| \(D\) | Diameter of one round clarifier | m |
Method and standards
Definitions.
Where it is used
- Clarifier sizing.
- Capacity checks on expansion.
Common mistakes
- Peak juice flow ignored.
Assumptions and limits
- Plug flow.
- The area here is the plan area of one compartment, V/H, and so depends on the depth chosen. Settling capacity depends on area, not depth (Hugot); check the area against the mud settling velocity with the clarifier settling area calculator. For a multi-tray clarifier the settling area is the sum of the trays.
References
- V = Q t
- A = V/H (definitions); retention and depth by design practice (Rein, Cane Sugar Engineering)
Questions and answers
Long or short retention?
Long retention gives margin but inverts sucrose; modern designs use short retention.
Area or volume?
Settling needs area; volume follows from depth.
Trays?
Multi-tray clarifiers add area for the same footprint: divide the area among trays.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.