FireCADCalc

Critical Crack Size and Stress Intensity (LEFM)

Stress intensity factor for a crack and the critical crack size at which it reaches the fracture toughness, from stress, geometry factor and K_Ic.

Inputs

Examples: Edge crack, steelCentre crack, aluminium

1.12 for a shallow edge crack, 1.0 for a centre crack in a wide plate; from a handbook for other shapes.

Results

Linear-elastic fracture mechanics; tough, ductile steels yield first and need elastic-plastic methods. Compare the failure stress with the yield strength: if it is higher, the part yields before it fractures and LEFM does not apply.

Stress intensity factor (MPa·m^½)26.587
Critical crack size8.8419mm
Failure stress for the crack141.05MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Edge crack, steel. The inputs, in the units selected above:

InputValue
Applied stress200.00 MPa
Geometry factor1.1200 -
Fracture toughness (MPa·m^½)50.000 -
Crack size (depth or half-length)5.0000 mm

Applying the formula below gives:

ResultValue
Stress intensity factor (MPa·m^½)28.074
Critical crack size15.860 mm
Failure stress for the crack356.20 MPa

Open this example in the calculator and change any input.

Formula

\(K_I = Y\sigma\sqrt{\pi a}, \quad a_c = \frac{1}{\pi}\left(\frac{K_{Ic}}{Y\sigma}\right)^2\)

Variables

Symbol Meaning SI unit
\(\sigma\) Applied stress Pa
\(Y\) Geometry factor -
\(K_{Ic}\) Fracture toughness (MPa·m½) -
\(a\) Crack size (depth or half-length) m
\(K_I\) Stress intensity factor (MPa·m½) -
\(a_c\) Critical crack size m
\(\sigma_f\) Failure stress for the crack Pa

Method and standards

LEFM.

Where it is used

  • Inspection acceptance and fitness for service screening.
  • Examinations.

Common mistakes

  • Full crack length instead of half for centre cracks.
  • Toughness at the wrong temperature.

Assumptions and limits

  • Small-scale yielding: the failure stress must be well below the yield strength, which is not an input here.
  • With no crack (a = 0) the failure stress is not shown.
  • K_Ic and K_I are entered and shown in MPa·m^½ as their labels say; the unit lists do not convert them.

References

  • K_I = Yσ√(πa); fracture when K_I = K_Ic (Irwin; linear-elastic fracture mechanics)

Questions and answers

200 MPa, edge crack, K_Ic 50 MPa·m^½?

Critical depth about 15.9 mm.

A 5 mm crack?

K about 28.1 MPa·m^½, below toughness.

Why low temperature matters?

Ferritic steel toughness drops sharply below its transition temperature.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.