Upper and lower bounds; real transverse moduli lie above Reuss (Halpin–Tsai is closer).

Longitudinal modulus (Voigt)139.40GPa
Transverse modulus (Reuss)8.5547GPa
Composite density1,560.0kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: E-glass/epoxy 55 %. The inputs, in the units selected above:

InputValue
Fibre volume fraction55.000 %
Fibre modulus72.000 GPa
Matrix modulus3.2000 GPa
Fibre density2,550.0 kg/m³
Matrix density1,200.0 kg/m³

Applying the formula below gives:

ResultValue
Longitudinal modulus (Voigt)41.040 GPa
Transverse modulus (Reuss)6.7447 GPa
Composite density1,942.5 kg/m³

Open this example in the calculator and change any input.

Formula

\(E_L = V_f E_f + (1 - V_f)E_m, \quad \frac{1}{E_T} = \frac{V_f}{E_f} + \frac{1 - V_f}{E_m}\)

Variables

Symbol Meaning SI unit
\(V_f\) Fibre volume fraction -
\(E_f\) Fibre modulus Pa
\(E_m\) Matrix modulus Pa
\(\rho_f\) Fibre density kg/m³
\(\rho_m\) Matrix density kg/m³
\(E_L\) Longitudinal modulus (Voigt) Pa
\(E_T\) Transverse modulus (Reuss) Pa
\(\rho_c\) Composite density kg/m³

Method and standards

Rule of mixtures.

Where it is used

  • FRP ducts, stacks and tanks.
  • Composite repairs.

Common mistakes

  • Mass instead of volume fraction.
  • Using Voigt across the fibres.

Assumptions and limits

  • Continuous aligned fibres, perfect bonding.

References

  • Voigt (iso-strain) and Reuss (iso-stress) bounds of the rule of mixtures

Questions and answers

55 % E-glass in epoxy?

About 41.0 GPa along the fibres, 6.7 GPa across them.

Woven or random fibres?

Lower: roughly half (woven) or a third (random) of the longitudinal value.

Strength?

Strength depends on defects and fibre length; mixtures only bound stiffness well.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.