FireCADCalc

Service Life at Another Temperature (Arrhenius Ageing)

Life of insulation, elastomers or lubricants at a new temperature from a known life and activation energy, with the acceleration factor.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 20,000 h at 90 °C, run at 110 °C, 80 kJ/molClass F 155 °C, 20,000 h, run cooler at 130 °C, 100 kJ/mol

Results

Single-mechanism Arrhenius model. The familiar 'life halves every 10 K' for insulation corresponds to E_a ≈ 80 kJ/mol near 100 °C. Do not extrapolate across a change of mechanism (melting, glass transition).

Life at the new temperature114,173h
Acceleration factor L₁/L₂0.17517
Temperature rise that halves life near T₁10.565K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 20,000 h at 90 °C, run at 110 °C, 80 kJ/mol. The inputs, in the units selected above:

InputValue
Known life20,000 h
Temperature for the known life90.000 °C
New temperature110.00 °C
Activation energy80.000 kJ/mol

Applying the formula below gives:

ResultValue
Life at the new temperature5,016.4 h
Acceleration factor L₁/L₂3.9870
Temperature rise that halves life near T₁9.5004 K

Open this example in the calculator and change any input.

Formula

\(L_2 = L_1\exp\left[\frac{E_a}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right)\right], \quad \Delta T_{1/2} \approx \frac{RT_1^2\ln2}{E_a}\)

Variables

Symbol Meaning SI unit
\(L_1\) Known life s
\(T_1\) Temperature for the known life K
\(T_2\) New temperature K
\(E_a\) Activation energy J/mol
\(L_2\) Life at the new temperature s
\(AF\) Acceleration factor L₁/L₂ -
\(\Delta T_{1/2}\) Temperature rise that halves life near T₁ K

Method and standards

Arrhenius relation.

Where it is used

  • Motor and transformer insulation life.
  • Elastomer seals and hoses.

Common mistakes

  • Extrapolating across a change of mechanism.
  • Using °C instead of kelvin.

Assumptions and limits

  • Single thermally activated mechanism.

References

  • Arrhenius ageing L ∝ exp(E_a/RT) (IEC 60216 principle; Montsinger's 10 K rule as a special case)

Questions and answers

Where does the 10 K rule come from?

With activation energy near 80 kJ/mol around 100 °C, a 10 K rise doubles the reaction rate and halves life.

How do I find E_a?

From ageing tests at two or more temperatures, or from the material's thermal endurance data.

What do the defaults represent?

A material good for 20,000 h at 90 °C, run at 110 °C, with E_a = 80 kJ/mol.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.