FireCADCalc

Sacrificial Anode Resistance and Current Output (Dwight)

Resistance to earth of a vertical cylindrical anode by Dwight's formula, its current output for the driving voltage and the number of anodes for a current demand.

Inputs

Examples: Illustrative magnesium anode column in 20 ohm m soilZinc anode in seawaterHigh-resistivity soil

Accepted: 10,000 to 1E+11 Ω·mm²/m
Accepted: 0.05 to 50 m
Accepted: 5 to 2,000 mm
Accepted: 0.01 to 50 V
Accepted: 0.0001 to 10,000 A

Results

Dwight's formula for a vertical rod of length L and diameter d in uniform earth is R = ρ/(2πL)[ln(8L/d) − 1]. With backfill of much lower resistivity, use the backfill column's dimensions. The anode delivers I = ΔV/R, where ΔV is the difference between the anode's closed-circuit potential and the structure's protected potential: about 0.25 V for zinc, 0.3 V for aluminium and 0.65–0.9 V for magnesium against −0.85 V CSE. Anodes in a group interfere, so a group needs more anodes than this simple division.

Anode resistance to earth0.13457Ω
Current output per anode1.8578A
Anodes needed (rounded up)7.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative magnesium anode column in 20 ohm m soil. The inputs, in the units selected above:

InputValue
Soil or water resistivity2.0000e+07 Ω·mm²/m
Anode (or backfill column) length1.5000 m
Anode (or backfill column) diameter200.00 mm
Driving voltage (anode to protected structure)0.70000 V
Total protection current required0.60000 A

Applying the formula below gives:

ResultValue
Anode resistance to earth6.5664 Ω
Current output per anode0.10660 A
Anodes needed (rounded up)6.0000

Open this example in the calculator and change any input.

Formula

\(R_a = \frac{\rho}{2\pi L}\left[\ln\frac{8L}{d} - 1\right], \quad I_a = \frac{\Delta V}{R_a}\)

Variables

Symbol Meaning SI unit
\(\rho\) Soil or water resistivity Ω·m
\(L\) Anode (or backfill column) length m
\(d\) Anode (or backfill column) diameter m
\(\Delta V\) Driving voltage (anode to protected structure) V
\(I_{req}\) Total protection current required A
\(R_a\) Anode resistance to earth Ω
\(I_a\) Current output per anode A
\(N\) Anodes needed (rounded up) -

Method and standards

Anode resistance.

Where it is used

  • Galvanic CP design for pipelines and tanks.
  • Checking anode output from soil surveys.

Common mistakes

  • Using the bare anode size when backfill controls.
  • Ignoring mutual interference in groups.

Assumptions and limits

  • Single vertical anode in uniform resistivity; top at the surface neglected.

References

  • Dwight's resistance of a vertical rod

Questions and answers

Why are magnesium anodes used in soil?

Their higher driving voltage pushes useful current through high-resistivity soil.

Does the anode's life follow from this?

Divide the anode's usable charge (mass × capacity × utilisation) by its current; see the anode mass calculator.

What do the defaults represent?

An illustrative 1.5 m × 200 mm backfilled magnesium anode column in 20 Ω·m soil with 0.7 V drive and 0.6 A demand.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Peabody, Control of Pipeline Corrosion, 2nd ed. (NACE, 2001)

Related calculators