Limiting Current Density and Oxygen-Controlled Corrosion Rate

Diffusion-limited current density of a cathodic reaction such as oxygen reduction, and the corrosion rate it supports, from diffusivity and boundary layer.

Inputs

Examples: Illustrative steel in still aerated waterStirred seawater, thin layerCopper, dissolved oxygen in warm water

Accepted: 1E-7 to 0.001 cm²/s
Accepted: 0.0001 to 10,000 mmol/L
Accepted: 1 to 8
Accepted: 0.001 to 10 mm
Accepted: 1 to 300 kg/kmol
Accepted: 1 to 4
Accepted: 500 to 25,000 kg/m³

Results

Concentration polarisation: a cathodic reaction cannot run faster than its reactant diffuses through the boundary layer, i_L = nFDC_B/δ. In neutral aerated water, corrosion of steel is controlled by oxygen reduction at this limit, so the corrosion rate equals i_L converted by Faraday's law. Stirring or flow thins δ and raises the rate; deaeration lowers C_B. Air-saturated water at 25 °C holds about 0.26 mol/m³ O₂.

Limiting current density3.2419A/m²
Equivalent uniform corrosion rate3.7620mm/a
Mass loss rate81.060g/(m²·d)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative steel in still aerated water. The inputs, in the units selected above:

InputValue
Diffusivity of the reactant2.0000e-05 cm²/s
Bulk concentration of the reactant0.26000 mmol/L
Electrons per reactant molecule (O₂: 4)4.0000 -
Diffusion boundary layer thickness0.50000 mm
Corroding metal molar mass55.845 kg/kmol
Metal valence2.0000 -
Metal density7,870.0 kg/m³

Applying the formula below gives:

ResultValue
Limiting current density0.40138 A/m²
Equivalent uniform corrosion rate0.46578 mm/a
Mass loss rate10.036 g/(m²·d)

Open this example in the calculator and change any input.

Formula

\(i_L = \frac{nFDC_B}{\delta}, \quad CR = \frac{i_LM}{zF\rho}\)

Variables

Symbol Meaning SI unit
\(D\) Diffusivity of the reactant m²/s
\(C_B\) Bulk concentration of the reactant mol/m³
\(n\) Electrons per reactant molecule (O₂: 4) -
\(\delta\) Diffusion boundary layer thickness m
\(M\) Corroding metal molar mass kg/kmol
\(z\) Metal valence -
\(\rho\) Metal density kg/m³
\(i_L\) Limiting current density A/m²
\(CR\) Equivalent uniform corrosion rate m/s
\(\dot m''\) Mass loss rate kg/(m²·s)

Method and standards

Limiting current.

Where it is used

  • Corrosion in cooling and process water.
  • Effect of flow and deaeration.

Common mistakes

  • Using mg/L of oxygen as mol/m³.
  • Ignoring flow effects on δ.

Assumptions and limits

  • Diffusion-controlled cathode; uniform corrosion.

References

  • Concentration polarisation and diffusion control

Questions and answers

Why does flow increase corrosion in neutral water?

It thins the diffusion layer, letting oxygen reach the surface faster.

How does deaeration help boilers?

Removing oxygen removes the cathodic reactant, cutting the limiting current and the corrosion rate.

What do the defaults represent?

Steel in air-saturated still water: O₂ at 0.26 mol/m³, D 2 × 10⁻⁹ m²/s, 0.5 mm boundary layer.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fontana, Corrosion Engineering, 3rd ed. (McGraw-Hill, 1986)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.