FireCADCalc

Hydrogen Permeation Flux Through a Steel Wall

Steady hydrogen permeation flux through a metal wall from Sieverts solubility and diffusivity with hydrogen pressures on both sides, and the time lag.

Inputs

Examples: Illustrative 10 mm wall at 100 barPipeline 20 mm, 70 bar, trapped steelThin membrane 1 mm, both sides pressurised

Accepted: 1E-5 to 10,000 bar
Accepted: 0 to 10,000 bar
Accepted: 1E-11 to 0.01 cm²/s
Accepted: 1E-9 to 1
Accepted: 0.01 to 300 mm

Results

Hydrogen dissolves as atoms, so its concentration follows Sieverts' law c = K_s√p; Fick's first law then gives J = D·K_s(√p₁ − √p₂)/L (as H₂). The time lag L²/6D is how long the flux takes to build up. Traps (inclusions, dislocations) cut the effective D at room temperature by orders of magnitude; electrochemical charging (corrosion, cathodic protection) can give much higher surface concentrations than the gas pressure suggests.

Dissolved hydrogen at the high-pressure face (mol/m³)0.013294
Permeation flux (mol H₂/(m²·s))3.3234e-08
Mass flux0.005789g/(m²·d)
Permeation time lag0.009259h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 mm wall at 100 bar. The inputs, in the units selected above:

InputValue
Hydrogen partial pressure, high side100.00 bar
Hydrogen partial pressure, low side0 bar
Hydrogen diffusivity in the metal1.0000e-05 cm²/s
Sieverts constant (mol H₂/(m³·Pa^½))9.4000e-06 -
Wall thickness10.000 mm

Applying the formula below gives:

ResultValue
Dissolved hydrogen at the high-pressure face (mol/m³)0.029725
Permeation flux (mol H₂/(m²·s))2.9725e-09
Mass flux5.1776e-04 g/(m²·d)
Permeation time lag4.6296 h

Open this example in the calculator and change any input.

Formula

\(c = K_s\sqrt p, \quad J = \frac{DK_s(\sqrt{p_1} - \sqrt{p_2})}{L}, \quad t_L = \frac{L^2}{6D}\)

Variables

Symbol Meaning SI unit
\(p_1\) Hydrogen partial pressure, high side Pa
\(p_2\) Hydrogen partial pressure, low side Pa
\(D\) Hydrogen diffusivity in the metal m²/s
\(K_s\) Sieverts constant (mol H₂/(m³·Pa^½)) -
\(L\) Wall thickness m
\(c_1\) Dissolved hydrogen at the high-pressure face (mol/m³) -
\(J\) Permeation flux (mol H₂/(m²·s)) -
\(J_m\) Mass flux kg/(m²·s)
\(t_L\) Permeation time lag s

Method and standards

Permeation.

Where it is used

  • Hydrogen pipelines and vessels.
  • Hydrogen embrittlement screening.

Common mistakes

  • Using p instead of √p.
  • Lattice D at room temperature in trapped steels.

Assumptions and limits

  • Steady state; surface equilibrium (no surface-limited entry); constant D.

References

  • Sieverts' law and Fick's first law

Questions and answers

Why the square root of pressure?

Molecular hydrogen splits into atoms on dissolving, so solubility goes as √p.

Does permeation cause damage?

The dissolved hydrogen, not the flux itself, causes embrittlement and blistering at traps and inclusions.

What do the defaults represent?

An illustrative 10 mm steel wall at 100 bar hydrogen, trap-affected D 1 × 10⁻⁹ m²/s and K_s 9.4 × 10⁻⁶ mol/(m³·Pa^½).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fontana, Corrosion Engineering, 3rd ed. (McGraw-Hill, 1986), Callister and Rethwisch, Materials Science and Engineering: An Introduction (Wiley)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.