District Heating Pipe Heat Capacity, Pressure Drop and Pump Power

Heat a district heating pipe can carry at a velocity and temperature difference, with the water flow, pressure drop over its length and pumping power.

Food, dairy and textile

Inputs

Examples: Illustrative DN150 at 1.5 m/s, 90/50 C, 1 kmLarge DN500 at 2.5 m/s, 120/60 CLow-temperature DN80 at 0.8 m/s, 65/35 C

Accepted: 10 to 2,000 mm
Accepted: 0.1 to 5 m/s
Accepted: 26.85 to 156.85 °C
Accepted: 16.85 to 146.85 °C
Accepted: 1 to 100,000 m
Accepted: 0 to 1 mm
Accepted: 20 to 100 %

Results

Flow at the return-side density; heat from IAPWS-IF97 enthalpies at 6 bar; Darcy–Weisbach with Colebrook friction over flow and return pipes, no fittings. Design velocities rise with pipe size (about 1 m/s small, 2–3 m/s large); a larger temperature difference carries more heat in the same pipe.

Water mass flow94.306t/h
Heat capacity4.3888MW
Pressure drop flow and return248.61kPa
Pump power9.4142kW
Pump power per heat delivered0.21451%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative DN150 at 1.5 m/s, 90/50 C, 1 km. The inputs, in the units selected above:

InputValue
Pipe inside diameter150.00 mm
Water velocity1.5000 m/s
Supply temperature90.000 °C
Return temperature50.000 °C
Route length (flow and return each)1,000.0 m
Pipe roughness0.050000 mm
Pump efficiency70.000 %

Applying the formula below gives:

ResultValue
Water mass flow94.306 t/h
Heat capacity4.3888 MW
Pressure drop flow and return248.61 kPa
Pump power9.4142 kW
Pump power per heat delivered0.21451 %

Open this example in the calculator and change any input.

Formula

\(\dot Q = \rho vA\,(h_s - h_r), \quad \Delta p = 2f\frac{L}{D}\frac{\rho v^2}{2}, \quad P_p = \frac{\dot V\Delta p}{\eta_p}\)

Variables

Symbol Meaning SI unit
\(D\) Pipe inside diameter m
\(v\) Water velocity m/s
\(T_s\) Supply temperature K
\(T_r\) Return temperature K
\(L\) Route length (flow and return each) m
\(\varepsilon\) Pipe roughness m
\(\eta_p\) Pump efficiency -
\(\dot m\) Water mass flow kg/s
\(\dot Q\) Heat capacity W
\(\Delta p\) Pressure drop flow and return Pa
\(P_p\) Pump power W
\(P_p/\dot Q\) Pump power per heat delivered -

Method and standards

Heat main capacity.

Where it is used

  • District heating network design.
  • Checking spare capacity for new connections.

Common mistakes

  • Designing with too small a ΔT.
  • Ignoring fittings and valves in Δp.

Assumptions and limits

  • Steady flow; equal flow and return length.

References

  • Hydraulic and thermal capacity of a heat main
  • Darcy–Weisbach with Colebrook friction

Questions and answers

Why does ΔT matter so much?

Heat carried is ṁc_pΔT: doubling the temperature difference doubles capacity with the same pipe and pumping.

How much pump power do networks use?

Usually about 0.5–2 % of the heat delivered; much more means pipes are undersized.

What do the defaults represent?

An illustrative DN150 main at 1.5 m/s with 90 °C supply and 50 °C return over 1 km, smooth steel, 70 % pump.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.