FireCADCalc

Weibull Wind Parameters from Mean and Standard Deviation

Weibull shape and scale factors from the mean and standard deviation of wind speed, the energy pattern factor, mean wind power density and time above a speed.

Inputs

Examples: Mean 10 m/s, sigma 5 m/s (near Rayleigh)Madison airport: mean 4.27 m/s, sigma 2.41 m/s, density 1.216

Accepted: 0.1 to 50 m/s
Accepted: 0.05 to 40 m/s
Accepted: 0.5 to 1.5 kg/m³
Accepted: 0 to 60 m/s

Results

k and c solve Ū = cΓ(1 + 1/k) and σ²/Ū² = Γ(1 + 2/k)/Γ²(1 + 1/k) − 1 together. k = 2 is the Rayleigh distribution. Two sites with the same mean speed can differ greatly in power because the power goes with the mean of U³.

Weibull shape factor2.1013
Weibull scale factor11.291m/s
Energy pattern factor1.8208
Mean wind power density1,115.2W/m²
Power density from the mean speed alone612.50W/m²
Fraction of time above U_x32.091%
Standard deviation of a Rayleigh distribution with the same mean5.2272m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Mean 10 m/s, sigma 5 m/s (near Rayleigh). The inputs, in the units selected above:

InputValue
Mean wind speed10.000 m/s
Standard deviation of wind speed5.0000 m/s
Air density1.2250 kg/m³
Wind speed of interest (for time above it)12.000 m/s

Applying the formula below gives:

ResultValue
Weibull shape factor2.1013
Weibull scale factor11.291 m/s
Energy pattern factor1.8208
Mean wind power density1,115.2 W/m²
Power density from the mean speed alone612.50 W/m²
Fraction of time above U_x32.091 %
Standard deviation of a Rayleigh distribution with the same mean5.2272 m/s

Open this example in the calculator and change any input.

Formula

\(\bar U = c\,\Gamma\left(1 + \frac{1}{k}\right), \quad \frac{\sigma^2}{\bar U^2} = \frac{\Gamma(1 + 2/k)}{\Gamma^2(1 + 1/k)} - 1\)

\(K_e = \frac{\Gamma(1 + 3/k)}{\Gamma^3(1 + 1/k)}, \quad \frac{P}{A} = \frac{\rho c^3}{2}\Gamma\left(1 + \frac{3}{k}\right), \quad 1 - F(U) = e^{-(U/c)^k}\)

Variables

Symbol Meaning SI unit
\(\bar U\) Mean wind speed m/s
\(\sigma\) Standard deviation of wind speed m/s
\(\rho\) Air density kg/m³
\(U_x\) Wind speed of interest (for time above it) m/s
\(k\) Weibull shape factor -
\(c\) Weibull scale factor m/s
\(K_e\) Energy pattern factor -
\(P/A\) Mean wind power density W/m²
\(\rho\bar U^3/2\) Power density from the mean speed alone W/m²
\(1 - F(U_x)\) Fraction of time above U_x -
\(\sigma_{Rayleigh}\) Standard deviation of a Rayleigh distribution with the same mean m/s

Method and standards

Method of moments for the two-parameter Weibull distribution of wind speed.

Where it is used

  • Wind resource screening from mean and standard deviation.
  • Comparing sites with the same mean speed.

Common mistakes

  • Estimating power from the mean speed cubed.
  • Mixing hub-height and 10 m statistics.

Assumptions and limits

  • Two-parameter Weibull; calms not separated.

Questions and answers

What is the energy pattern factor?

The ratio of the true mean power of the wind to the power computed from the mean speed cubed; it is always above 1 and grows as the wind becomes more variable.

What k should I expect?

Inland sites often have k ≈ 2 (Rayleigh); steady trade-wind and coastal sites reach 3 or more; very gusty sites fall below 1.5.

What do the defaults represent?

An illustrative case: Mean 10 m/s, sigma 5 m/s (near Rayleigh). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 24.2, eqs. 24.2.5 to 24.2.13 and Example 24.2.2

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.