Worked example
Example: Illustrative 3 MW, 120 m, 7 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean wind speed at hub height | 7.0000 m/s |
| Rated power | 3.0000 MW |
| Rotor diameter | 120.00 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capacity factor | 40.067 % |
| Annual energy | 10,530 MWh |
| Rating over diameter squared (kW/m²) | 0.20833 |
Open this example in the calculator and change any input.
Formula
\(CF = 0.087\bar V - \frac{P_R}{D^2}, \quad E = CF \cdot P_R \cdot 8{,}760\,\text{h}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\bar V\) | Mean wind speed at hub height | m/s |
| \(P_R\) | Rated power | W |
| \(D\) | Rotor diameter | m |
| \(CF\) | Capacity factor | - |
| \(E\) | Annual energy | J |
| \(P_R/D^2\) | Rating over diameter squared (kW/m²) | - |
Method and standards
Empirical capacity factor.
Where it is used
- Early project screening.
- Comparing turbine models for a site.
Common mistakes
- Using the 10 m mean speed instead of hub height.
- Using it for very low or very high winds.
Assumptions and limits
- Rayleigh winds; typical pitch-regulated power curves; no losses.
References
- Empirical capacity-factor correlation for Rayleigh winds
Questions and answers
What capacity factors do wind farms achieve?
About 25–35 % onshore and 40–50 % offshore; low-specific-rating turbines on good sites exceed 40 % on land.
Why does a bigger rotor raise the capacity factor?
More swept area for the same generator reaches rated power at lower winds, so the machine spends more of the year near full output.
What do the defaults represent?
An illustrative 3 MW turbine with a 120 m rotor at a site with a 7 m/s mean wind at hub height.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 6