Worked example
Example: Illustrative 6.5 m/s at 10 m to 100 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Measured wind speed | 6.5000 m/s |
| Measurement height | 10.000 m |
| Height of interest (hub height) | 100.00 m |
| Power-law exponent (1/7 = 0.143 open land) | 0.14300 - |
| Surface roughness length (0.03 m open grassland) | 0.030000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Speed at z₂, power law | 9.0347 m/s |
| Speed at z₂, log law | 9.0764 m/s |
| Power density ratio, power law | 2.6853 |
| Power density ratio, log law | 2.7227 |
| Power-law exponent equivalent to the log law between z₁ and z₂ | 0.14500 |
Open this example in the calculator and change any input.
Formula
\(U_2 = U_1\left(\frac{z_2}{z_1}\right)^\alpha, \quad U_2 = U_1\frac{\ln(z_2/z_0)}{\ln(z_1/z_0)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(U_1\) | Measured wind speed | m/s |
| \(z_1\) | Measurement height | m |
| \(z_2\) | Height of interest (hub height) | m |
| \(\alpha\) | Power-law exponent (1/7 = 0.143 open land) | - |
| \(z_0\) | Surface roughness length (0.03 m open grassland) | m |
| \(U_2\) | Speed at z₂, power law | m/s |
| \((U_2/U_1)^3\) | Power density ratio, power law | - |
| \(\alpha_{eq}\) | Power-law exponent equivalent to the log law between z₁ and z₂ | - |
Method and standards
Wind profile laws.
Where it is used
- Wind resource assessment from met-mast data.
- Small turbine siting from airport anemometers.
Common mistakes
- Using 1/7 at all sites (forests and night-time stable air give much more shear).
- Extrapolating far above the measurement height.
Assumptions and limits
- Neutral stability; flat homogeneous terrain.
References
- Power-law and logarithmic wind profiles
Questions and answers
How much more energy at 100 m than at 10 m?
With α = 1/7 the speed rises by 39 % and the power density by 2.7 times.
What roughness lengths are typical?
About 0.0002 m over open sea, 0.03 m for open farmland, 0.1–0.25 m for crops and hedges and 0.5–1 m for forests and towns.
What do the defaults represent?
An illustrative 6.5 m/s measured at 10 m, extrapolated to a 100 m hub with α = 1/7 and z₀ = 0.03 m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 2