FireCADCalc

Wind-Diesel Hybrid Fuel Saving

Diesel output, fuel use and fuel saved when wind power supplies part of an isolated load, with the diesel's minimum load and a linear fuel curve.

Thermal power plant

Inputs

Examples: Illustrative 400 kW load, 250 kW windHigh wind: dumpingLow wind 50 kW

Accepted: 1 to 100,000 kW
Accepted: 0 to 100,000 kW
Accepted: 1 to 100,000 kW
Accepted: 0 to 70 %
Accepted: 0 to 0.3
Accepted: 0.1 to 0.5

Results

Diesel follows the net load but not below its minimum; surplus wind is dumped. Fuel F = aP_r + bP (L/h with powers in kW); the default a and b are a common generic curve. Because of the no-load term, fuel falls less than output: switching diesels off, storage or dump loads with useful heat raise the saving.

Diesel output with wind150.00kW
Wind power used250.00kW
Wind power dumped0kW
Fuel without wind (L/h)140.47
Fuel with wind (L/h)78.975
Fuel saving43.780%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 400 kW load, 250 kW wind. The inputs, in the units selected above:

InputValue
Load400.00 kW
Wind power available250.00 kW
Diesel rated power500.00 kW
Diesel minimum load (fraction of rating)30.000 %
Fuel curve no-load coefficient (L per kWh of rating)0.084150 -
Fuel curve slope (L per kWh of output)0.24600 -

Applying the formula below gives:

ResultValue
Diesel output with wind150.00 kW
Wind power used250.00 kW
Wind power dumped0 kW
Fuel without wind (L/h)140.47
Fuel with wind (L/h)78.975
Fuel saving43.780 %

Open this example in the calculator and change any input.

Formula

\(P_d = \max(f_{min}P_r,\;P_L - P_w), \quad F = aP_r + bP_d\)

Variables

Symbol Meaning SI unit
\(P_L\) Load W
\(P_w\) Wind power available W
\(P_r\) Diesel rated power W
\(f_{min}\) Diesel minimum load (fraction of rating) -
\(a\) Fuel curve no-load coefficient (L per kWh of rating) -
\(b\) Fuel curve slope (L per kWh of output) -
\(P_d\) Diesel output with wind W
\(P_{w,used}\) Wind power used W
\(P_{dump}\) Wind power dumped W
\(F_0\) Fuel without wind (L/h) -
\(F\) Fuel with wind (L/h) -
\(1 - F/F_0\) Fuel saving -

Method and standards

Hybrid dispatch.

Where it is used

  • Island and mine power systems.
  • Screening wind retrofits to diesel grids.

Common mistakes

  • Assuming fuel falls in proportion to output.
  • Ignoring spinning reserve requirements.

Assumptions and limits

  • One diesel running; steady snapshot.

References

  • Linear diesel fuel curve with minimum load

Questions and answers

Why is the saving less than the wind share?

A running diesel burns fuel even at no load, and it cannot go below its minimum load, so some wind is dumped.

How can more wind be used?

Run fewer or smaller diesels, add batteries or a flywheel, and use surplus wind for heating or water pumping.

What do the defaults represent?

An illustrative 400 kW load, 250 kW of wind and a 500 kW diesel with a 30 % minimum load and a generic fuel curve.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.