Worked example
Example: Illustrative 90 m, 4 m x 25 mm, 150 t, 6-13 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tower height | 90.000 m |
| Tower outer diameter (uniform equivalent) | 4.0000 m |
| Wall thickness | 25.000 mm |
| Young's modulus | 210.00 GPa |
| Steel density | 7,850.0 kg/m³ |
| Top mass (nacelle and rotor) | 150.00 t |
| Minimum rotor speed | 6.0000 rpm |
| Maximum rotor speed | 13.000 rpm |
| Number of blades | 3.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| First tower bending frequency | 0.25851 Hz |
| Tower mass | 220.57 t |
| 1P at minimum speed | 0.10000 Hz |
| 1P at maximum speed | 0.21667 Hz |
| Blade passing at minimum speed | 0.30000 Hz |
| Blade passing at maximum speed | 0.65000 Hz |
Open this example in the calculator and change any input.
Formula
\(f_1 = \frac{1}{2\pi}\sqrt{\frac{3EI}{(M + \frac{33}{140}m_t)L^3}}, \quad f_{1P} = \frac{n}{60}, \quad f_{BP} = B\frac{n}{60}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Tower height | m |
| \(D\) | Tower outer diameter (uniform equivalent) | m |
| \(t\) | Wall thickness | m |
| \(E\) | Young's modulus | Pa |
| \(\rho_s\) | Steel density | kg/m³ |
| \(M\) | Top mass (nacelle and rotor) | kg |
| \(n_{min}\) | Minimum rotor speed | rad/s |
| \(n_{max}\) | Maximum rotor speed | rad/s |
| \(B\) | Number of blades | - |
| \(f_1\) | First tower bending frequency | 1/s |
| \(m_t\) | Tower mass | kg |
| \(1P_{min}\) | 1P at minimum speed | 1/s |
| \(1P_{max}\) | 1P at maximum speed | 1/s |
| \(BP_{min}\) | Blade passing at minimum speed | 1/s |
| \(BP_{max}\) | Blade passing at maximum speed | 1/s |
Method and standards
Tower frequency screening.
Where it is used
- Tower and foundation preliminary design.
- Retrofits with heavier nacelles.
Common mistakes
- Ignoring foundation flexibility.
- Using the maximum rotor speed only (variable-speed rotors sweep a band).
Assumptions and limits
- Uniform tube; fixed base; Rayleigh approximation.
References
- Cantilever with tip mass (Rayleigh) and rotor excitation bands
Questions and answers
Why must the tower avoid 1P and 3P?
Rotor imbalance excites the tower once per revolution (1P) and each blade passing the tower excites it B times per revolution; resonance would multiply the fatigue loads.
Why are most towers soft-stiff?
A tower between the two bands needs less steel than a stiff-stiff tower and avoids the control effort of a soft-soft design.
What do the defaults represent?
An illustrative 90 m steel tube 4 m in diameter with a 25 mm wall, 150 t on top, rotor 6–13 rpm, three blades.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 6 and 7