Worked example
Example: Illustrative 3 x 105 dB(A) at 500 m, 35 dB background. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Sound power level of one turbine | 105.00 - |
| Distance from the hub to the receiver | 500.00 m |
| Air absorption coefficient (dB per m; about 0.005 for A-weighted broadband) | 0.005000 - |
| Number of turbines at about this distance | 3.0000 - |
| Background sound level (0 to ignore) | 35.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Level from one turbine (dB) | 40.539 |
| Level from all n turbines (dB) | 45.310 |
| Turbines plus background (dB) | 45.697 |
| Increase over background (dB) | 10.697 |
Open this example in the calculator and change any input.
Formula
\(L_p = L_W - 10\log_{10}(2\pi R^2) - \alpha R, \quad L_{p,n} = L_p + 10\log_{10}n\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_W\) | Sound power level of one turbine | - |
| \(R\) | Distance from the hub to the receiver | m |
| \(\alpha\) | Air absorption coefficient (dB per m; about 0.005 for A-weighted broadband) | - |
| \(n\) | Number of turbines at about this distance | - |
| \(L_{bg}\) | Background sound level (0 to ignore) | - |
| \(L_{p,1}\) | Level from one turbine (dB) | - |
| \(L_{p,n}\) | Level from all n turbines (dB) | - |
| \(L_{total}\) | Turbines plus background (dB) | - |
| \(\Delta L\) | Increase over background (dB) | - |
Method and standards
Hemispherical noise propagation.
Where it is used
- Setback and planning screening.
- Community noise complaint checks.
Common mistakes
- Adding decibels arithmetically.
- Using the distance from the tower base instead of the hub.
Assumptions and limits
- Point sources over flat reflecting ground; broadband A-weighted levels.
References
- Hemispherical spreading with air absorption
Questions and answers
How loud is a turbine at 500 m?
A 105 dB(A) machine gives about 41 dB(A) at 500 m by this estimate, and three of them about 45 dB(A).
Why do levels add so slowly?
Decibels are logarithmic: doubling the number of equal sources adds only 3 dB.
What do the defaults represent?
An illustrative three turbines of 105 dB(A) sound power at 500 m, with 35 dB(A) background.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 12