Worked example
Example: Illustrative three bins, m 4. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Load range 1 | 400.00 kN |
| Cycles at range 1 | 1,000,000 - |
| Load range 2 | 800.00 kN |
| Cycles at range 2 | 100,000 - |
| Load range 3 | 1,500.0 kN |
| Cycles at range 3 | 10,000 - |
| Load range 4 | 0 kN |
| Cycles at range 4 | 0 - |
| Load range 5 | 0 kN |
| Cycles at range 5 | 0 - |
| S-N curve slope (steel welds 3–5, composites about 10) | 4.0000 - |
| Equivalent number of cycles | 1.0000e+07 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Damage-equivalent load range | 329.02 kN |
| Total cycles | 1,110,000 |
| Share of damage from the worst bin | 43.201 % |
Open this example in the calculator and change any input.
Formula
\(DEL = \left(\frac{\sum_i n_iS_i^m}{N_{eq}}\right)^{1/m}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S_1\) | Load range 1 | N |
| \(n_1\) | Cycles at range 1 | - |
| \(S_2\) | Load range 2 | N |
| \(n_2\) | Cycles at range 2 | - |
| \(S_3\) | Load range 3 | N |
| \(n_3\) | Cycles at range 3 | - |
| \(S_4\) | Load range 4 | N |
| \(n_4\) | Cycles at range 4 | - |
| \(S_5\) | Load range 5 | N |
| \(n_5\) | Cycles at range 5 | - |
| \(m\) | S-N curve slope (steel welds 3–5, composites about 10) | - |
| \(N_{eq}\) | Equivalent number of cycles | - |
| \(DEL\) | Damage-equivalent load range | N |
| \(\sum n_i\) | Total cycles | - |
| \(\max(n_iS_i^m)/\sum\) | Share of damage from the worst bin | - |
Method and standards
Equivalent fatigue load.
Where it is used
- Comparing turbine load cases and sites.
- Fatigue screening of welded structures.
Common mistakes
- Mixing load ranges with amplitudes.
- Comparing DELs with different m or N_eq.
Assumptions and limits
- Linear damage accumulation; no mean-stress correction.
References
- Damage-equivalent load with Miner's rule
Questions and answers
Why is one bin often dominant?
Damage goes with the load range to the power m; with m = 10 for composites, rare large cycles outweigh millions of small ones.
What N_eq should I use?
A convention: often 10⁷ cycles, or 1 Hz over the design life; compare DELs only at the same N_eq and m.
What do the defaults represent?
An illustrative spectrum of 10⁶ cycles at 400 kN, 10⁵ at 800 kN and 10⁴ at 1,500 kN with m = 4 and N_eq = 10⁷.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 6