Worked example
Example: Illustrative 5D, C_T 0.8, k 0.075. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Thrust coefficient of the upstream turbine | 0.80000 - |
| Downstream distance | 500.00 m |
| Rotor diameter | 100.00 m |
| Wake decay constant (0.075 onshore, 0.04–0.05 offshore) | 0.075000 - |
| Number of equal overlapping wakes | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Axial induction (1 − √(1 − C_T))/2 | 0.27639 |
| Wake diameter at X | 175.00 m |
| Wind speed ratio in the wake | 0.81950 |
| Velocity deficit | 18.050 % |
| Power ratio of the downstream turbine (below rated) | 55.036 % |
| Spacing in rotor diameters | 5.0000 |
Open this example in the calculator and change any input.
Formula
\(\frac{U_X}{U_0} = 1 - \frac{1 - \sqrt{1 - C_T}}{\left(1 + 2kX/D\right)^2}, \quad D_X = D + 2kX\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_T\) | Thrust coefficient of the upstream turbine | - |
| \(X\) | Downstream distance | m |
| \(D\) | Rotor diameter | m |
| \(k\) | Wake decay constant (0.075 onshore, 0.04–0.05 offshore) | - |
| \(n\) | Number of equal overlapping wakes | - |
| \(a\) | Axial induction (1 − √(1 − C_T))/2 | - |
| \(D_X\) | Wake diameter at X | m |
| \(U_X/U_0\) | Wind speed ratio in the wake | - |
| \(1 - U_X/U_0\) | Velocity deficit | - |
| \((U_X/U_0)^3\) | Power ratio of the downstream turbine (below rated) | - |
| \(X/D\) | Spacing in rotor diameters | - |
Method and standards
Top-hat wake model.
Where it is used
- Wind farm layout screening.
- Estimating array losses.
Common mistakes
- Applying full-wake losses for all wind directions.
- Using the onshore k offshore.
Assumptions and limits
- Full wake overlap; neutral atmosphere; below rated wind speed for the power ratio.
References
- Jensen (Park) wake model
Questions and answers
How far apart should turbines be?
Typically 5–9 diameters in the prevailing wind direction and 3–5 across it. In a full wake at 5D the Jensen model gives a speed deficit near 18 % and a power loss of about 45 %; averaged over all wind directions, array losses are usually 5–15 %.
Why is k smaller offshore?
Lower ambient turbulence over the sea means wakes recover more slowly.
What do the defaults represent?
An illustrative 100 m rotor with C_T 0.8, a turbine 500 m (5D) downstream, k = 0.075, single wake.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Katic, Højstrup and Jensen, A simple model for cluster efficiency, European Wind Energy Association Conference (1986), Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 9