Worked example
Example: Illustrative 100 m hub, 120 m rotor, 15 m/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Hub height | 100.00 m |
| Rotor diameter | 120.00 m |
| Wind speed at hub height (for ice fall) | 15.000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ice throw distance (rotating) | 330.00 m |
| Ice fall distance (stopped) | 160.00 m |
| Tip height | 160.00 m |
Open this example in the calculator and change any input.
Formula
\(d_{throw} = 1.5(D + H), \quad d_{fall} = \frac{U(D/2 + H)}{15}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(H\) | Hub height | m |
| \(D\) | Rotor diameter | m |
| \(U\) | Wind speed at hub height (for ice fall) | m/s |
| \(d_{throw}\) | Ice throw distance (rotating) | m |
| \(d_{fall}\) | Ice fall distance (stopped) | m |
| \(H + D/2\) | Tip height | m |
Method and standards
Ice throw screening.
Where it is used
- Siting near roads, paths and buildings.
- Cold-climate operating procedures.
Common mistakes
- Using the fall distance for an operating turbine.
- Treating screening distances as a full risk assessment.
Assumptions and limits
- Empirical; flat terrain.
References
- Seifert empirical ice throw and ice fall distances
Questions and answers
How far can ice be thrown?
By the Seifert rule about 1.5 times the sum of rotor diameter and hub height, around 330 m for a 100 m hub and 120 m rotor.
How is the risk managed?
Ice detection that stops the turbine, warning signs, and closing paths or roads within the zone during icing.
What do the defaults represent?
An illustrative 100 m hub, 120 m rotor, with a 15 m/s wind for ice falling from a stopped rotor.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Seifert, Westerhellweg and Kröning, Risk analysis of ice throw from wind turbines, BOREAS VI (2003)