Worked example
Example: Illustrative 5 m rotor, 5 m/s, 20 m head. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rotor diameter | 5.0000 m |
| Mean wind speed | 5.0000 m/s |
| Rotor power coefficient (multi-blade about 0.3) | 0.30000 - |
| Transmission and pump efficiency | 60.000 % |
| Energy pattern factor (mean of U³ over Ū³; Rayleigh 1.91) | 1.9100 - |
| Total pumping head | 20.000 m |
| Air density | 1.2000 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean wind power through the rotor | 2.8127 kW |
| Mean hydraulic power | 0.50629 kW |
| Mean flow | 9.2928 m³/h |
| Water per day | 223.03 m³ |
Open this example in the calculator and change any input.
Formula
\(\bar P_h = \frac{1}{2}\rho\frac{\pi D^2}{4}K_e\bar U^3C_P\eta_p, \quad \bar Q = \frac{\bar P_h}{\rho_wgH}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(D\) | Rotor diameter | m |
| \(\bar U\) | Mean wind speed | m/s |
| \(C_P\) | Rotor power coefficient (multi-blade about 0.3) | - |
| \(\eta_p\) | Transmission and pump efficiency | - |
| \(K_e\) | Energy pattern factor (mean of U³ over Ū³; Rayleigh 1.91) | - |
| \(H\) | Total pumping head | m |
| \(\rho\) | Air density | kg/m³ |
| \(\bar P_w\) | Mean wind power through the rotor | W |
| \(\bar P_h\) | Mean hydraulic power | W |
| \(\bar Q\) | Mean flow | m³/s |
| \(V_d\) | Water per day | m³ |
Method and standards
Wind pumping energy balance.
Where it is used
- Livestock and village water supply.
- Comparing wind and solar pumping.
Common mistakes
- Cubing the mean wind without the energy pattern factor.
- Ignoring furling and start-up limits.
Assumptions and limits
- Mean-power estimate; constant efficiencies.
References
- Wind power with an energy pattern factor applied to pumping
Questions and answers
How much water does a farm windmill lift?
About 200 m³ a day against 20 m for a 5 m rotor in a 5 m/s mean wind by this mean-power estimate; real farm windmills often deliver about half of that.
Why do water-pumping windmills have many blades?
High solidity gives high starting torque at low tip speed ratio, which suits piston pumps; their C_P is lower (about 0.3) than fast electric rotors.
What do the defaults represent?
An illustrative 5 m multi-blade rotor in a 5 m/s mean wind (Rayleigh), C_P 0.30, 60 % pump efficiency and 20 m head.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 10, Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)