Wind Turbine Yaw Misalignment Power Loss

Power and annual energy lost when a wind turbine rotor is misaligned with the wind, by the cosine-power law with an adjustable exponent.

Thermal power plant

Inputs

Examples: Illustrative 8 deg, n 2, 9000 MWhcos-cubed 15 degSmall 4 deg, n 1.8

Accepted: 0 to 57.296 °
Accepted: 1 to 4
Accepted: 0 to 27,778 MWh
Accepted: 0 to 100 %

Results

P = P₀cosⁿγ: momentum theory gives n = 3; field measurements on large turbines suggest about 1.8–2.5. Above rated, pitch control recovers the loss, so only the below-rated share of energy is affected.

Power ratio cosⁿγ98.063%
Power loss below rated1.9369%
Annual energy lost122.03MWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 8 deg, n 2, 9000 MWh. The inputs, in the units selected above:

InputValue
Yaw misalignment8.0000 °
Exponent (3 by momentum theory; measured about 1.8–2.5)2.0000 -
Annual energy when aligned9,000.0 MWh
Fraction of the year below rated with this error70.000 %

Applying the formula below gives:

ResultValue
Power ratio cosⁿγ98.063 %
Power loss below rated1.9369 %
Annual energy lost122.03 MWh

Open this example in the calculator and change any input.

Formula

\(\frac{P}{P_0} = \cos^n\gamma, \quad \Delta E = E f\left(1 - \cos^n\gamma\right)\)

Variables

Symbol Meaning SI unit
\(\gamma\) Yaw misalignment rad
\(n\) Exponent (3 by momentum theory; measured about 1.8–2.5) -
\(E\) Annual energy when aligned J
\(f\) Fraction of the year below rated with this error -
\(P/P_0\) Power ratio cosⁿγ -
\(1 - P/P_0\) Power loss below rated -
\(\Delta E\) Annual energy lost J

Method and standards

Yawed rotor power.

Where it is used

  • Performance audits and lidar alignment checks.
  • Estimating gains from yaw recalibration.

Common mistakes

  • Applying the loss above rated.
  • Assuming n = 3 without measurements.

Assumptions and limits

  • Steady yaw offset; uniform inflow.

References

  • Cosine law for yawed rotors

Questions and answers

How much does 8° of yaw error cost?

About 2 % of below-rated power with n = 2 and nearly 3 % with n = 3, enough to justify checking nacelle vane calibration.

Why do real turbines lose less than cos³?

Blade flexing, rotor tilt and inflow skew change the loading; measurements usually show an exponent near 2.

What do the defaults represent?

An illustrative 8° yaw error, exponent 2, on a turbine making 9,000 megawatt-hours a year with 70 % of its energy below rated.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.