Wind Power Curve Air Density Correction

Equivalent reference wind speed for a pitch-regulated turbine at a site's air density, the power ratio below rated and the shift in rated wind speed.

Thermal power plant

Inputs

Examples: Illustrative 8 m/s at 1.06 kg/m3Hot desert 1.12, 10 m/sCold dense 1.30

Accepted: 0.1 to 40 m/s
Accepted: 0.5 to 1.5 kg/m³
Accepted: 0.5 to 1.5 kg/m³
Accepted: 3 to 30 m/s

Results

Pitch-regulated machines: read the reference power curve at V_n = V(ρ/ρ₀)^(1/3), so the curve shifts to higher wind speeds at low density while rated power is unchanged. Stall-regulated machines: scale power by ρ/ρ₀. This is the usual power-curve normalisation method.

Equivalent speed to read on the reference curve7.6234m/s
Power ratio below rated (stall or same speed)86.531%
Rated wind speed at the site density12.068m/s
Shift in rated wind speed0.56817m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 8 m/s at 1.06 kg/m3. The inputs, in the units selected above:

InputValue
Site wind speed8.0000 m/s
Site air density1.0600 kg/m³
Density of the reference power curve1.2250 kg/m³
Rated wind speed of the reference curve11.500 m/s

Applying the formula below gives:

ResultValue
Equivalent speed to read on the reference curve7.6234 m/s
Power ratio below rated (stall or same speed)86.531 %
Rated wind speed at the site density12.068 m/s
Shift in rated wind speed0.56817 m/s

Open this example in the calculator and change any input.

Formula

\(V_n = V\left(\frac{\rho}{\rho_0}\right)^{1/3}, \quad V_r = V_{r,0}\left(\frac{\rho_0}{\rho}\right)^{1/3}\)

Variables

Symbol Meaning SI unit
\(V\) Site wind speed m/s
\(\rho\) Site air density kg/m³
\(\rho_0\) Density of the reference power curve kg/m³
\(V_{r,0}\) Rated wind speed of the reference curve m/s
\(V_n\) Equivalent speed to read on the reference curve m/s
\(P/P_0\) Power ratio below rated (stall or same speed) -
\(V_{r}\) Rated wind speed at the site density m/s
\(V_r - V_{r,0}\) Shift in rated wind speed m/s

Method and standards

Power-curve density normalisation.

Where it is used

  • Energy yield at high or hot sites.
  • Power performance testing.

Common mistakes

  • Scaling rated power by density for pitch-regulated turbines.
  • Using sea-level curves unchanged at altitude.

Assumptions and limits

  • Same C_P at the same tip speed ratio; no Reynolds-number effects.

References

  • Air-density normalisation of wind turbine power curves

Questions and answers

How much does a high site lose?

At 1,500 m (ρ ≈ 1.06) power below rated falls by about 13 %, and rated power is reached about 0.6 m/s later.

Why use the cube root?

Power below rated goes as ρV³; keeping ρV³ equal gives the same power at V(ρ/ρ₀)^(1/3) on the reference curve.

What do the defaults represent?

An illustrative 8 m/s at a site with air density 1.06 kg/m³, reference curve at 1.225 kg/m³ with rated speed 11.5 m/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.