Worked example
Example: Mean 10 m/s, sigma 5 m/s (near Rayleigh). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean wind speed | 10.000 m/s |
| Standard deviation of wind speed | 5.0000 m/s |
| Air density | 1.2250 kg/m³ |
| Wind speed of interest (for time above it) | 12.000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Weibull shape factor | 2.1013 |
| Weibull scale factor | 11.291 m/s |
| Energy pattern factor | 1.8208 |
| Mean wind power density | 1,115.2 W/m² |
| Power density from the mean speed alone | 612.50 W/m² |
| Fraction of time above U_x | 32.091 % |
| Standard deviation of a Rayleigh distribution with the same mean | 5.2272 m/s |
Open this example in the calculator and change any input.
Formula
\(\bar U = c\,\Gamma\left(1 + \frac{1}{k}\right), \quad \frac{\sigma^2}{\bar U^2} = \frac{\Gamma(1 + 2/k)}{\Gamma^2(1 + 1/k)} - 1\)
\(K_e = \frac{\Gamma(1 + 3/k)}{\Gamma^3(1 + 1/k)}, \quad \frac{P}{A} = \frac{\rho c^3}{2}\Gamma\left(1 + \frac{3}{k}\right), \quad 1 - F(U) = e^{-(U/c)^k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\bar U\) | Mean wind speed | m/s |
| \(\sigma\) | Standard deviation of wind speed | m/s |
| \(\rho\) | Air density | kg/m³ |
| \(U_x\) | Wind speed of interest (for time above it) | m/s |
| \(k\) | Weibull shape factor | - |
| \(c\) | Weibull scale factor | m/s |
| \(K_e\) | Energy pattern factor | - |
| \(P/A\) | Mean wind power density | W/m² |
| \(\rho\bar U^3/2\) | Power density from the mean speed alone | W/m² |
| \(1 - F(U_x)\) | Fraction of time above U_x | - |
| \(\sigma_{Rayleigh}\) | Standard deviation of a Rayleigh distribution with the same mean | m/s |
Method and standards
Method of moments for the two-parameter Weibull distribution of wind speed.
Where it is used
- Wind resource screening from mean and standard deviation.
- Comparing sites with the same mean speed.
Common mistakes
- Estimating power from the mean speed cubed.
- Mixing hub-height and 10 m statistics.
Assumptions and limits
- Two-parameter Weibull; calms not separated.
Questions and answers
What is the energy pattern factor?
The ratio of the true mean power of the wind to the power computed from the mean speed cubed; it is always above 1 and grows as the wind becomes more variable.
What k should I expect?
Inland sites often have k ≈ 2 (Rayleigh); steady trade-wind and coastal sites reach 3 or more; very gusty sites fall below 1.5.
What do the defaults represent?
An illustrative case: Mean 10 m/s, sigma 5 m/s (near Rayleigh). Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 24.2, eqs. 24.2.5 to 24.2.13 and Example 24.2.2