Wind Water Pump (Windmill) Output

Hydraulic power, flow and daily water volume of a mechanical or electrical wind pump from rotor size, mean wind speed, power coefficient, pump efficiency and head.

Food, dairy and textile

Inputs

Examples: Illustrative 5 m rotor, 5 m/s, 20 m headSmall 3 m, 4 m/s, 30 mElectric wind pump 10 m, 6 m/s, 40 m

Accepted: 0.5 to 30 m
Accepted: 1 to 15 m/s
Accepted: 0.05 to 0.5
Accepted: 10 to 100 %
Accepted: 1 to 5
Accepted: 1 to 300 m
Accepted: 0.5 to 1.5 kg/m³

Results

Mean hydraulic power = ½ρAK_eŪ³C_Pη_p; flow = P_h/(ρ_wgH) with water density 1,000 kg/m³. Mechanical windmills start at low wind but stall or furl in strong winds, so real daily output is usually below this mean-power estimate; use a tank for storage.

Mean wind power through the rotor0.51844kW
Mean hydraulic power0.072581kW
Mean flow0.88815m³/h
Water per day21.316m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5 m rotor, 5 m/s, 20 m head. The inputs, in the units selected above:

InputValue
Rotor diameter5.0000 m
Mean wind speed5.0000 m/s
Rotor power coefficient (multi-blade about 0.3)0.30000 -
Transmission and pump efficiency60.000 %
Energy pattern factor (mean of U³ over Ū³; Rayleigh 1.91)1.9100 -
Total pumping head20.000 m
Air density1.2000 kg/m³

Applying the formula below gives:

ResultValue
Mean wind power through the rotor2.8127 kW
Mean hydraulic power0.50629 kW
Mean flow9.2928 m³/h
Water per day223.03 m³

Open this example in the calculator and change any input.

Formula

\(\bar P_h = \frac{1}{2}\rho\frac{\pi D^2}{4}K_e\bar U^3C_P\eta_p, \quad \bar Q = \frac{\bar P_h}{\rho_wgH}\)

Variables

Symbol Meaning SI unit
\(D\) Rotor diameter m
\(\bar U\) Mean wind speed m/s
\(C_P\) Rotor power coefficient (multi-blade about 0.3) -
\(\eta_p\) Transmission and pump efficiency -
\(K_e\) Energy pattern factor (mean of U³ over Ū³; Rayleigh 1.91) -
\(H\) Total pumping head m
\(\rho\) Air density kg/m³
\(\bar P_w\) Mean wind power through the rotor W
\(\bar P_h\) Mean hydraulic power W
\(\bar Q\) Mean flow m³/s
\(V_d\) Water per day m³

Method and standards

Wind pumping energy balance.

Where it is used

  • Livestock and village water supply.
  • Comparing wind and solar pumping.

Common mistakes

  • Cubing the mean wind without the energy pattern factor.
  • Ignoring furling and start-up limits.

Assumptions and limits

  • Mean-power estimate; constant efficiencies.

References

  • Wind power with an energy pattern factor applied to pumping

Questions and answers

How much water does a farm windmill lift?

About 200 m³ a day against 20 m for a 5 m rotor in a 5 m/s mean wind by this mean-power estimate; real farm windmills often deliver about half of that.

Why do water-pumping windmills have many blades?

High solidity gives high starting torque at low tip speed ratio, which suits piston pumps; their C_P is lower (about 0.3) than fast electric rotors.

What do the defaults represent?

An illustrative 5 m multi-blade rotor in a 5 m/s mean wind (Rayleigh), C_P 0.30, 60 % pump efficiency and 20 m head.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 10, Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.