FireCADCalc

Wind Turbine Shadow Length and Flicker Frequency

Length of the shadow cast by a wind turbine rotor at a given sun elevation and the shadow flicker frequency from rotor speed and number of blades.

Thermal power plant

Inputs

Examples: Illustrative 100 m hub, 120 m rotor, sun 5 deg, 12 rpmSun 15 degSmall turbine 30 m, 20 m rotor, 3 deg, 40 rpm

Accepted: 5 to 200 m
Accepted: 1 to 300 m
Accepted: 0.57296 to 89.954 °
Accepted: 0.95493 to 1,909.9 rpm
Accepted: 1 to 6

Results

Shadow reach = (H + D/2)/tan β on flat ground. At low sun the shadow is long but faint: assessments usually ignore sun below about 3° and count only distances where the blade covers a significant part of the sun (often within about 10 rotor diameters).

Horizontal reach of the blade-tip shadow763.25m
Reach of the hub shadow572.43m
Flicker frequency2.0000Hz

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 100 m hub, 120 m rotor, sun 5 deg, 12 rpm. The inputs, in the units selected above:

InputValue
Hub height100.00 m
Rotor diameter120.00 m
Sun elevation5.0000 °
Rotor speed12.000 rpm
Number of blades3.0000 -

Applying the formula below gives:

ResultValue
Horizontal reach of the blade-tip shadow1,828.8 m
Reach of the hub shadow1,143.0 m
Flicker frequency0.60000 Hz

Open this example in the calculator and change any input.

Formula

\(L_s = \frac{H + D/2}{\tan\beta}, \quad f = \frac{Bn}{60}\)

Variables

Symbol Meaning SI unit
\(H\) Hub height m
\(D\) Rotor diameter m
\(\beta\) Sun elevation rad
\(n\) Rotor speed rad/s
\(B\) Number of blades -
\(L_s\) Horizontal reach of the blade-tip shadow m
\(L_h\) Reach of the hub shadow m
\(f\) Flicker frequency 1/s

Method and standards

Shadow geometry.

Where it is used

  • Siting near homes and roads.
  • Planning flicker assessments.

Common mistakes

  • Counting shadows at sun elevations below 3°.
  • Ignoring that houses behind trees or hills are shaded anyway.

Assumptions and limits

  • Flat ground; sun as a point.

References

  • Geometric shadow projection

Questions and answers

Why is flicker limited to some distance?

Far away the blade covers only a small part of the sun's disc, so the light barely changes; guidance usually assesses within about 10 rotor diameters.

What flicker frequency do large turbines give?

About 0.5–1 Hz (three blades at 10–20 rpm), well below the range that triggers photosensitive epilepsy.

What do the defaults represent?

An illustrative 100 m hub, 120 m rotor at 12 rpm with the sun 5° above the horizon.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 12

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.