FireCADCalc

Wind Turbine Rated Wind Speed and Specific Rating

Rated wind speed at which a turbine reaches rated power from rotor size, power coefficient and drive-train efficiency, with the specific rating in W/m².

Thermal power plant

Inputs

Examples: Illustrative 3.5 MW, 130 mOffshore 15 MW, 240 mSmall 10 kW, 7 m, Cp 0.35, high site

Accepted: 0.0001 to 20 MW
Accepted: 0.5 to 300 m
Accepted: 0.1 to 0.593
Accepted: 50 to 100 %
Accepted: 0.5 to 1.5 kg/m³

Results

U_r = [2P_r/(ρAC_Pη)]^(1/3). Low specific rating (about 200–300 W/m²) suits low-wind sites and raises the capacity factor; offshore machines run near 350–450 W/m².

Rated wind speed10.059m/s
Specific rating263.69W/m²
Swept area13,273m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 3.5 MW, 130 m. The inputs, in the units selected above:

InputValue
Rated electrical power3.5000 MW
Rotor diameter130.00 m
Rotor power coefficient near rated0.45000 -
Drive-train and generator efficiency94.000 %
Air density1.2250 kg/m³

Applying the formula below gives:

ResultValue
Rated wind speed10.059 m/s
Specific rating263.69 W/m²
Swept area13,273 m²

Open this example in the calculator and change any input.

Formula

\(U_r = \left(\frac{2P_r}{\rho AC_P\eta}\right)^{1/3}, \quad \frac{P_r}{A} = \frac{4P_r}{\pi D^2}\)

Variables

Symbol Meaning SI unit
\(P_r\) Rated electrical power W
\(D\) Rotor diameter m
\(C_P\) Rotor power coefficient near rated -
\(\eta\) Drive-train and generator efficiency -
\(\rho\) Air density kg/m³
\(U_r\) Rated wind speed m/s
\(P_r/A\) Specific rating W/m²
\(A\) Swept area m²

Method and standards

Rated-power balance.

Where it is used

  • Turbine selection for a site's wind class.
  • Comparing turbine models.

Common mistakes

  • Using the Betz limit for C_P.
  • Ignoring air density at hot or high sites.

Assumptions and limits

  • Steady wind; C_P constant up to rated.

References

  • Rotor power equation at rated conditions

Questions and answers

What rated speeds do modern turbines have?

About 10–13 m/s; large rotors on smaller generators (low specific rating) reach rated at lower speeds.

Why not use the largest possible generator?

Winds above rated are rare; a smaller generator on a big rotor produces more of the year at full output for less cost.

What do the defaults represent?

An illustrative 3.5 MW turbine with a 130 m rotor, C_P 0.45 and 94 % drive-train efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 9, Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 6

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.