Worked example
Example: Illustrative 3.5 MW, 130 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Rated electrical power | 3.5000 MW |
| Rotor diameter | 130.00 m |
| Rotor power coefficient near rated | 0.45000 - |
| Drive-train and generator efficiency | 94.000 % |
| Air density | 1.2250 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Rated wind speed | 10.059 m/s |
| Specific rating | 263.69 W/m² |
| Swept area | 13,273 m² |
Open this example in the calculator and change any input.
Formula
\(U_r = \left(\frac{2P_r}{\rho AC_P\eta}\right)^{1/3}, \quad \frac{P_r}{A} = \frac{4P_r}{\pi D^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P_r\) | Rated electrical power | W |
| \(D\) | Rotor diameter | m |
| \(C_P\) | Rotor power coefficient near rated | - |
| \(\eta\) | Drive-train and generator efficiency | - |
| \(\rho\) | Air density | kg/m³ |
| \(U_r\) | Rated wind speed | m/s |
| \(P_r/A\) | Specific rating | W/m² |
| \(A\) | Swept area | m² |
Method and standards
Rated-power balance.
Where it is used
- Turbine selection for a site's wind class.
- Comparing turbine models.
Common mistakes
- Using the Betz limit for C_P.
- Ignoring air density at hot or high sites.
Assumptions and limits
- Steady wind; C_P constant up to rated.
References
- Rotor power equation at rated conditions
Questions and answers
What rated speeds do modern turbines have?
About 10–13 m/s; large rotors on smaller generators (low specific rating) reach rated at lower speeds.
Why not use the largest possible generator?
Winds above rated are rare; a smaller generator on a big rotor produces more of the year at full output for less cost.
What do the defaults represent?
An illustrative 3.5 MW turbine with a 130 m rotor, C_P 0.45 and 94 % drive-train efficiency.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed. (Wiley, 2009), ch. 9, Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 6